Product Specifications

Tube Banks5 Tubes
Inner TubesC.I.
Outer TubesM.S.
Concrete Raft9 Thick
Impeller BladesAerofoil
Draft SystemBoth
Heat TransferHigher
FeaturesEfficient Drying, Versatile Fuel, Easy Install, Better Sealing, Steady Temp

Product Overview

Key Features


TIGL introduces the most efficient 5 pass SHOLA - V heater to minimise the TEA drying cost.

Shola-V is a cellular multitubular header specially designed for the Tea industry. The salient features of this heater are the double vertical rows of tube on either side of the grate which aids in either 3 pass or 5 pass of the flue gas. These heaters can be fired with either coal, leco, firewood, gas, or oil.

Since its introduction, these heaters have found wide acceptance in factories large and small not only in India, but also in other Tea producing countries like Bangladesh, Kenya, Tanzania, Indonesia, Sri Lanka, Uganda, Malawi, Malaysia.



Shola - V Principle



In the Shola - V heater, hot flue gases drawn by an induced draught created over the grate by the ID Fan & Chimney pass through 2 vertical rows of Tube- bundles on either side of the grate and over the cast surfaces. Ambient fresh air drawn from the sides, back and top by the dryer fan, picks up heat from the heated surfaces and enters the drying chamber. The principle of both 3 pass and 5 pass is the same except that in 5 pass hot air is made to pass five times in the tube banks as against 3 times in the 3 pass. So heat transfer area is increased by more then 1.5 times & this improves the heater efficiency.

Salient Features & Advantages:

  • Tube banks : Shola-V heaters are fitted with tube banks instead of individual tubes. Each tube banks consists of 5 tubes. The tube banks are grooved at each joint to fit asbestos rope packing for better sealing. The number of tube banks vary according to the size of the heater. For better heat transfer, the inner tubes are made of C.I. And the outer tubes are made of M.S.
  • Foundation : The heater is erected on a firm and rigid concrete base. A concrete raft of 9a a thick on solid earth is sufficient and no excavation is required. The heater is mounted on the concrete raft.
  • Draft System : Shola-V heaters are designed to handle both Induced and Forced air draughts. For maximum efficiency the fans are specially designed with aerofoil impeller blades which deliver the required quantum of hot air with low power consumption. Inlet dampers are provided in the fan for better air control.
  • Mechanical Stoking (optional) : Shola-V heaters can be conveniently fitted with mechanical stokers for uniform feeding of coal. This helps to maintain steady temperature as well as reduces coal consumption.
  • Easy Installation : Entire Shola-V heater arch bars, tube banks, front plate, back plate, smoke box, side plates etc. Are made in parts so that handling is easy. All these parts are designed in such a way that they can be bolted together with asbestos tape sealing, so that installation can be done within a short time.
  • Heat Transfer : Shola-V heaters are designed with higher heat transfer area and flue gases pass 5 times or 3 times before escaping into the atmosphere . This improves the efficiency of the heater . Moreover, since the flue gases pass through the tubes instead of over them, the tubes can be cleaned and maintained for better heat transfer.
  • Materials : All castings are of superior quality and they are property cleaned & fettled before assembly. Special Graded heat resistant casting are used where heater has to cope with higher temperature, i.e. when LECO is fired or while using high temperatures. In 5-pass heaters the outer tube banks are made of special M.S tubes for better heat transfer.
  • Heat Insulation : The entire inner surface of front plate and retaining bolts are insulated with special heat resistant compound. The angle cleats which are welded to the fan suction ducts are insulated with special lagging compound for better insulation.

HIGHLIGHTS :


  • Multiple Models : Shola-V heaters are available in different sizes with both 3 pass & 5 pass. The biggest model Shola-V Jumbo produces usable heat of 20.6 lacs Kcal/hr.
  • Better Heat Transfer : Shola-V heaters are specially designed for better heat transfer. The efficiency varies from 55-65% depending on model.
  • Low Power & Coal Consumption : Due to better heat transfer the coal consumption per kg of made tea is less than 0.6 kg and power is also less by 25% in the 5-pass heaters, under normal conditional of use.
  • Better Retention Of Heat : Shola-V heaters are constructed with better and high quality heat resistant materials, so heat loss is very minimal.
  • Long Life Of Castings : All parts exposed to direct heat are made of special superior casting, so they last much longer. All castings except tube banks and arch bars are guaranteed for 5 years.
  • No Maintenance : Since there are no moving parts, maintenance is very minimal expect cleaning of tube banks.
  • Easy & Quick Installation : No excavations and no foundation bolts are required, since there are no moving parts. Moreover, the machine is supplied in dismantled condition for ease installation and handling.
  • Versatile : Shola-V heaters can be coupled with any type of dryer.

Specifications:



































































































DESCRIPTION10CM 5 pass14CM 5 passSPECIAL 16CM 5 pass16CM 5 pass18CM 5 pass
No.Of Arch Bars(Back+Centre+Front)2+16+22+16+22+16+22+16+22+16+2
Grate Area Ft2 m211.3 1.0512.9 1.2016.1 1.520 1.8523.7 2.2
No.of Tube BundlesC.IM.SRH LH TOTAL 6+6=12 3+3=6 RH LH TOTAL 8+8+16 3+3=6 RH LH TOTAL 10+10=20 3+3=6RH LH TOTAL 10+10=20 3+3=6RH LH TOTAL 10+10=20 3+3=6
Fifth Pass Tube M.S6+6=126+6=127+7=147+7=147+7=14
Tube Length in each passmminch1.840 72.51.840 72.51.840 72.52,310 912,310 91
Coal Burning Capacity with coal having NCV 5000 K.Cal/kgA.Mechanical sokerB.Manual feed170 145200 170250 210300 260360 300
Heat Generation CapacityA.Mechanical sokerB.Manual feed850000 7250001000000 8500001250000 10500001500000 13000001800000 1500000
Air Requirement for combustionCFM3,500-6,5004,200-7,2005,000-9,0005,500-11,0007,000-13,500
Over All Size(L*W*H) in mm5350*4270*26405850*4270*30205850*4270*34506040*5440*34506490*5440*3450
Over All WeightApprox.in.kgs.1640019000230002800029500

Note:-Due to a continuous process of development the design is subject to change without notice.

Company Details

T & I GLOBAL LIMITED (TIGL) is a leading manufacturer and exporter of Tea Processing Machinery with the expertise to supply Customised processing equipment for CTC, Orthodox & Green Tea. The company is a family-run business and was established in 1949 by the industrious Bagaria family hailing from Assam, India. Over the years, the group has launched many innovative products and value additions for the tea industry, as well as Customized Drying Solutions for the food and chemical industries. Today its reputation and goodwill has taken the company to all Tea producing countries around the world. TIGL has two full fledged manufacturing facilities in India - at Kolkata the capital city of West Bengal, and at Coimbatore, the industrial city of Tamil Nadu. Sales and service are facilitated through domestic offices in Coimbatore, Kolkata, Coonor ( Nilgiris), Siliguri (North Bengal) and Tinsukia (Assam), and overseas offices in Colombo, Sri Lanka, Nairobi, Kenya, and Hanoi, Vietnam. A technical team of over 50 experienced engineers is deployed through these offices to ensure prompt deliveries and commissioning. In addition to these facilities, the company's R & D unit and Pilot Laboratory at Coimbatore are consistently involved in product development and innovation. TIGL is a Government recognised export house, with a global market share in excess of 40%, commanding an enviable export market in Srilanka, Bangladesh, Nepal, Burma, Australia, Indonesia, South Africa, Kenya, Uganda, Zimbabwe, Malawi, Ethiopia, Nigeria, Rwanda, Tanzania, Brazil, Columbia, Vietnam, Sri Lanka, Malaysia, Thailand, China, Philippines and Papua New Guinea. Its domestic market includes blue-chip companies like Tata Tea, Williamson Magor, Harrisons Malayalam Limited, Warren Tea, KDHP, Parry Agro and Goodricke Tea, etc.

Business Type

Exporter, Manufacturer, Supplier

Establishment

1949

Working Days

Monday To Sunday

GST NO

19AAACT8460G1Z4

Related Products

Explore Related Categories

More Product From This seller

Seller Details

GST

GST - 19AAACT8460G1Z4

5 RatingRating

Kolkata, West Bengal

Executive Chairman

Mr. Sajjan Bagaria

Address

11, Jassal House, 4-A, Auckland Square, Kolkata, West Bengal, 700017, India

industrial heaters in Kolkata

Report incorrect details

People Also Viewed