Key Features
Yaskawa AC Drive A1000 is a fully featured drive providing outstanding performance, flexibility, quality and environmental friendliness. This drive helps control the functioning of simple fans and pumps to complex machines. The brand is world renowned for designing and manufacturing world class AC/DC drives, panels, motors, and various other electrical products. As a trusted supplier and exporter, we are working hard to provide the best quality to customers all over the world. The Yaskawa AC Drive A1000 is mainly used in electrical appliances and machinery production units.
Features:
- Made of finest parts and components for optimum performance and long service life
- Available in high technical specifications in compliance with national and international standards
- Superlative performance and hassle free operation
- Functional under tough ambient conditions
AC Drives (A1000)
Technical Specification
Standard Specifications |
| 2 | 4 | 5 | 7 | 11 | 18 | 23 | 31 | 38 | 44 | 58 | 72 | 88 | 103 | 139 | 165 | 208 | 250 | 296 | 362 | 414 | 515 | 675 | ||
Typical Motor | Normal Duty | 0.75 | 1.5 | 2.2 | 3 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 185 | 220 | 250 | 355 | ||
Capacity | Heavy Duty | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 185 | 220 | 315 | ||
Rated Output | Normal Duty | 1.6 | 3.1 | 4.1 | 5.3 | 8.5 | 13.3 | 17.5 | 24 | 29 | 34 | 44 | 55 | 67 | 78 | 106 | 126 | 159 | 191 | 226 | 276 | 316 | 392 | 514 | ||
Capacity in KVA | Heavy Duty | 1.4 | 2.6 | 3.7 | 4.2 | 7 | 11.3 | 13.7 | 18.3 | 24 | 30 | 34 | 46 | 57 | 69 | 85 | 114 | 137 | 165 | 198 | 232 | 282 | 343 | 461 | ||
Rated Output | Normal Duty | 2.4 | 4.1 | 5.4 | 6.9 | 11.1 | 17.5 | 23 | 31 | 38 | 44 | 58 | 72 | 88 | 103 | 139 | 165 | 208 | 250 | 296 | 362 | 414 | 515 | 675 | ||
Current A | Heavy Duty | 1.8 | 3.4 | 4.8 | 5.5 | 9.2 | 14.8 | 18 | 24 | 31 | 39 | 45 | 60 | 75 | 91 | 112 | 150 | 180 | 216 | 260 | 304 | 370 | 450 | 605 | ||
Enclosure Type | NE MA-1 (Can be used as IP00 by removing top & bottom covers) | IP00 | ||||||||||||||||||||||||
Overload Tolerance | Normal Duty Rating:120% of rated output current for 60s | Heavy Duty Rating: 150% of rated output current for 60 s | ||||||||||||||||||||||||
Max. Output Voltage | Proportional to input voltage | |||||||||||||||||||||||||
Max. Output Frequency | 400 Hz | |||||||||||||||||||||||||
Rated Voltage/Rated Frequency | Three-Phase 380 to 480 VAC, 50/60 Hz | |||||||||||||||||||||||||
Allowable Voltage Fluctuation | -15% to +10% | |||||||||||||||||||||||||
Allowable Frequency Fluctuation | 5% | |||||||||||||||||||||||||
Harmonic Suppression | DC Reactor | Option | Built-in | |||||||||||||||||||||||
Braking Function | Braking Chopper | Built-in | Option | |||||||||||||||||||||||
Control Characteristics | Control Method | V/f Control, with PG, Open Loop Vector Control, Closed Loop Vector Control with PG, Open Loop Vector Control For PM, Advanced Open Loop Vector Control for PM , Closed Loop Control for PM. | ||||||||||||||||||||||||
Frequency Control Range | 0.01 to 400 Hz | |||||||||||||||||||||||||
Frequency Setting Resolution | Digital reference: 0.01 Hz | |||||||||||||||||||||||||
| ||||||||||||||||||||||||||
Analog reference: 0.03 Hz/60 Hz (11 bit) | ||||||||||||||||||||||||||
Output Frequency Resolution | 0.001 Hz | |||||||||||||||||||||||||
Frequency Setting Signal | -10 to +10 V, 0 to +10 V, 4 to 20MA, pulse train | |||||||||||||||||||||||||
Starting Torque | 150%/3 Hz (V/f Control and V/f Control with PG), 200%/0.3 Hz (Open Loop Vector Control), 200%/0 RPM (Closed Loop Vector Control, Closed Loop Vector Control fro PM, and Advanced Open Loop Vector Control for PM), 100%/5% Speed (Open Loop Vector Control for PM | |||||||||||||||||||||||||
Speed control Range | 1:1500 (closed loop vector control and closed loop vector control for PM) | |||||||||||||||||||||||||
| ||||||||||||||||||||||||||
1:200 (Open loop vector control) 1:40)V/f control with PG) | ||||||||||||||||||||||||||
| ||||||||||||||||||||||||||
1:20 (Open loop vector control for PM) 1:100 (Advanced Open loop vector control for PM | ||||||||||||||||||||||||||
Speed Control Accuracy | +0.2% n Open Loop Vector Control (25oC+10oC) +0.2% in Closed Loop vector control (25oC+10oC) | |||||||||||||||||||||||||
Speed Response | 10 Hz in Open loop vector control 25oC+10oC), 50 Hz in Closed loop vector control (25oC+10oc) (Excludes temperature fluctuation when performing Rotational Auto Tuning) | |||||||||||||||||||||||||
Axel/Decel Time | 0.00 to 6000.0 s (4 selectable combinations of independent acceleration and deceleration settings) | |||||||||||||||||||||||||
Braking Torque | Drives of 200/400V 30kW or less have a built-in braking transistor | |||||||||||||||||||||||||
| ||||||||||||||||||||||||||
(Over excitation Deceleration, High slip Braking: Approx 40%) | ||||||||||||||||||||||||||
| ||||||||||||||||||||||||||
Continuous Regen. Torque: approx: 20% 125% with dynamic braking resistor option: 10% ED, 10s, internal braking transistor | ||||||||||||||||||||||||||
V/f Characteristics | User-selected programs and V/f preset patterns possible | |||||||||||||||||||||||||
Main Control Functions | Torque Control, Droop Control, Speed/Torque Control switch, Feed Forward Control, Zero Servo Control, Momentary, Power Loss Ride-Thru, Speed Search, Over Torque detection, Torque limit, 17 step Speed (Max.), Axel/decel, time switch, S-curve accel/decel, 3-wire sequence, Auto-Tuning (rotational, stationary), On line Tunign, Dwell control. | |||||||||||||||||||||||||
Protection Functions | Motor Protection | Motor Overheat protection based on output current | ||||||||||||||||||||||||
Over Voltage Protection | 200 V class: Stops when DC bus exceeds approx. 410 V, 400 V class: Stops when DC bus exceeds approx. 820 V | |||||||||||||||||||||||||
Under voltage Protection | 200 V class: Stops when DC bus exceeds approx. 190 V, 400 V class: Stops when DC bus exceeds approx. 380 V | |||||||||||||||||||||||||
Momentary Power Loss Ride-Thru | Stops immediately after 15 ms or longer power loss )default). Continuous operation during power up to 2s (standard) | |||||||||||||||||||||||||
Stall Prevention | Stall prevention during acceleration/deceleration and constant speed operation | |||||||||||||||||||||||||
Ground Fault Protection | Protection by electronic circuit | |||||||||||||||||||||||||
Interface | Charge LED | Charge LED remains lit until DC bus has fallen below approx. 50 V | ||||||||||||||||||||||||
Digital Inputs | 8 nos. programmable (24 VDC Sink/Source/External supply configurable) | |||||||||||||||||||||||||
Digital Outputs | 4 nos. (1Fixed/3 programmable )2 nos. open collector-48 | |||||||||||||||||||||||||
| ||||||||||||||||||||||||||
VDC & 2nos. Relay- 230VAC/30VDC | ||||||||||||||||||||||||||
Analog Inputs | 3 nos. programmable - 2 nos. 0 to + 10 VDC & 1 no./0/4 to 20MA | |||||||||||||||||||||||||
Analog Outputs | 2 nos. Programmable- 10 to +10 VDC | |||||||||||||||||||||||||
Pulse Train I/O | 0 to 32 kHz max. -1 no. input & 1 no. output | |||||||||||||||||||||||||
Communication | Mod bus RS422/RS485 with speed up to 115.2 kbps | |||||||||||||||||||||||||
Safety I/O | 2 nos. hardware base block inputs & 1 no. safety electronic device monitor output (complying to UL508C, EN954-1 Ca 3, IEC/EN61508 SIL2) | |||||||||||||||||||||||||
| I/O | Analog Input (AI-A3)-3 AI, Digital Input (DI-A3)-16 DI, Analog Monitor (AO-A3)02AO, digital Output (DO-A3)- 8DO | ||||||||||||||||||||||||
Option | Encoder Interface | PG-B3 for Complimentary type PG up to 50 KHz, PG-X3 for Line Driver type PG up to 300 Khz | ||||||||||||||||||||||||
| Communication | PROFIBUS-DP (SI-P3), Device Net (SI-N3), CAN open (SI-S3), MECHATROLINK-2 (SI-T3) | ||||||||||||||||||||||||
| Others | LCD Operator, External 24 V supply; Braking Unit | ||||||||||||||||||||||||
| Area of use | Indoors | ||||||||||||||||||||||||
Environment | Ambient Temperature | -10 to +50oC | ||||||||||||||||||||||||
| Humidity | 95% RH or less (no condensation) | ||||||||||||||||||||||||
| Storage Temperature | -20 to 60oC (short-term temperature during transportation) | ||||||||||||||||||||||||
| Altitude | Up to 1000 meters | ||||||||||||||||||||||||
| Shock | 10 Hz to 20 Hz, 9.8 m/s2 max. 20 Hz, 5.9 m/s2 (400V:55 Kw-HD or more ) or 2.0 m/s2 max. (400V:75 Kw-HD or less) | ||||||||||||||||||||||||
| Standard compliance | RoHS compliant UL 508oC, en61800-5-1, EN954-1 Cat3, ISO 13849-1 )Cat3, PLD), IEC/EN61508 SIL2 |
Company Details
Focusing on a customer-centric approach, PRITHVI POWER ENGINEERS Pvt. Ltd. has a pan-India presence and caters to a huge consumer base throughout the country. Buy Industrial Automation in bulk from PRITHVI POWER ENGINEERS Pvt. Ltd. at Trade India quality-assured products.
Business Type
Exporter, Manufacturer, Distributor, Supplier, Trading Company
Employee Count
32
Establishment
1997
GST NO
09AAFCP3738E1ZD
Certification
International Wire Association, Instrumentation System and Association Society
Related Products
Explore Related Categories
More Product From This seller
Seller Details
GST - 09AAFCP3738E1ZD
Greater Noida, Uttar Pradesh
Managing Director
Mr. Avinash C. Vigh
Address
Plot No. 88, Ecotech II, Udyog Vihar Extn, Behind L.G., Greater Noida, Uttar Pradesh, 201301, India
yaskawa ac drive in Greater Noida
Report incorrect details