InterfaceRS 485Throughput100 MbpsModbus TypeModbus RTUNumber Of Ports1Usage/ApplicationIOTIP Access methodRemote MQTTNetwork Type4GBackplane Current Load0.3AColorBlackPower Supply12V Wall AdapterOperating Temperature70 Degrees CelsiusAntennaYesSim InterfaceMicro / Nano SimData Bits7/8ParityE/O/NOn-Board Flash Storage64KSupports multiple protocolsYesBrandHashStudiozMax Number Of Slaves30Per Slave Register Sets20 (Max 20 Regs In Each Set)Minimum Report Interval500msDigital Inputs5Details:Supports reading from up to 5 Modbus devices at the same time as reading from the Digital Input.Each slave can have different configurations and data speeds.It offers options for even, odd, or no parity settings with support for 7 or 8-bit frames.The device can perform repetitive polling of the Modbus slaves to extract data, which is then transmitted through the data channel.It supports both REST API and MQTT transmissions for data communication.FeaturesModbus Simplex:The gateway supports Modbus communication from 1200 bps to 115200 bps.Max number of Slaves:You can connect up to 5 Modbus slaves to the gateway.Per Slave Register Sets:Each slave can have up to 20 register sets, with a maximum of 20 registers in each set.Digital Inputs:The gateway has 5 digital inputs that can be monitored.Minimum Report Interval:The gateway can report data at a minimum interval of 500ms.Communication channel:RS-485SpecificationsOperating Voltage:The gateway operates on a voltage range of 6- 30V.Modbus Wire:It requires a twisted pair of shielded cable for Modbus communication, with a maximum cable length of 1200mtr.Digital Input Range:The digital inputs accept a voltage range of 3.5v to 30V, with a current of 0.09mA.SIM:The gateway uses a microSIM card with 4G data capability.Operating Voltage 6-30vModbus WireTwisted pair Shielded Cable Digital Input Range3.5v - 30v @0.09mAUse cases of 4G-LTE RS-485 Modbus Gateway with 5 Digital InputsIndustrial Automation and Control:The Modbus Gateway can connect to various industrial devices and equipment, allowing remote monitoring and control. The 5 digital inputs can be used to monitor the status of sensors, switches, or alarms in an industrial environment.Energy management systems:The gateway can integrate with energy meters, enabling real-time monitoring of energy consumption and facilitating energy management strategies. The digital inputs can be utilized to detect events such as power outages or equipment malfunctions.Building automation and security:In building automation systems, the gateway can connect to sensors and security devices such as motion detectors, door/window sensors, or fire alarms. The digital inputs can detect and report events like unauthorized access or potential security breaches.Environmental monitoring:With the help of environmental sensors connected to the digital inputs, the Modbus Gateway can monitor parameters like temperature, humidity, air quality, or water levels. This information can be used for environmental monitoring and control applications.Remote equipment monitoring and maintenance:By connecting the gateway to equipment or machinery, it becomes possible to monitor their operational status and receive real-time notifications about faults or anomalies. The digital inputs can detect signals indicating equipment failures or maintenance requirements.Smart agriculture:The Modbus Gateway can be used in agriculture to connect to sensors that monitor soil moisture, temperature, or irrigation systems. The digital inputs can help detect events such as water level fluctuations or weather changes, enabling efficient and automated farm management.