voice search
High Performance Electrocoagulation Unit - Electric Drive, 1 Cubic Meter Volume | Full Automatic Operation, 0.2kw Power Consumption, 90% Recycle Rate, Low Maintenance, Zero Chemical Additives

High Performance Electrocoagulation Unit - Electric Drive, 1 Cubic Meter Volume | Full Automatic Operation, 0.2kw Power Consumption, 90% Recycle Rate, Low Maintenance, Zero Chemical Additives

Price:

Get Latest Price

Minimum Order Quantity :

1

In Stock

In Stock

Product Specifications

Power Consumption0.2 Kilowatt (kW)
Water Out Conductivity100
Recycle Rate90%
Drive TypeElectric
Voltage100 Volt (v)
Product TypeEC
Volume1 Cubic Meter (m3)
Water SourceRiver Water
Automatic GradeFull Automatic
FOB PortShenzhen
Payment TermsPaypal, Western Union, Telegraphic Transfer (T/T)
Supply Ability10 Per Month
Delivery Time20 Days
Sample AvailableYes
Sample PolicyFree samples are available
Packaging DetailsPlywood case
Main Export Market(s)Australia, Middle East, South America, Asia, North America
Main Domestic MarketAll India
CertificationsCE

Product Overview

Key Features

Keeping in mind ever-evolving requirements of our respected clients, we are manufacturing and exporting a premium quality range of High Performance Electrocoagulation Unit in Shenzhen, Guangdong, China.

Appearance
Brief Introduction
Electrocoagulation (EC) uses a direct current to dissolve a parallel electrode unit and thereby introduces metal ions with a positive charge into the wastewater stream (fig 1). These ions are attracted to the very fine negatively charged droplets and particles of the contaminants. Repelling forces between the droplets and particles are broken and the dispersed particles combine into larger separable aggregates. The resulting agglomerations increase in size until they are no longer stable in an aqueous medium. Once destabilized, positively charged ions react with negatively charged particles in the water resulting in floc that approach a highly stable state. The flocs either sink or float, depending on the characteristics of the waste stream (fig 2). Simultaneously, gases formed by electroanalysis form very fine bubbles that associate with the coagulated contaminants and buoy them up for removal by flotation. Because the floc is highly stable it can then be easily separated from the water by a number of conventional secondary separation techniques.

In the electrocoagulation process, the electrical current is introduced into water via parallel plates constructed of various metals that are selected via different elimination to optimize the removal process. Several materials such as steel, aluminum, titanium and graphite are available for the reactor plates. Each material is specific to an application, although each can also treat a broad range within that application. Reactor design and plate selection are based on laboratory testing and our extensive experience with electrocoagulation.
Electrocoagulation operating effects are highly dependent on the chemistry of the aqueous medium, especially conductivity. Other influent characteristics such as pH, ionic charge, particle size, and chemical constituent concentrations will influence operating conditions. The flow rate of the aqueous medium through an electrocoagulation cell depends on the solution chemistry, the nature of the entrained suspension or emulsion, and the extent of electrocoagulation required to achieve the treatment objective. In addition, the treated effects of electrocoagulation also addresses the current and voltage.

Benefits

A. Low Capital Costs
A. Low Operating Costs
A. Low power requirements
A. Low maintenance
A. Generally no chemical additions
A. Small Space Requirements
A. Easy operation and high automation degree
A. Instantaneous Treatment
A. Handles a wide variation in the waste stream and treats multiple contaminants
A. Residual concentrations in effluent are far lower than most chemical processes
A. Sludge minimization
A. Sludge Stabilization
A. Consistent and reliable results
A. Comply with current and future regulations
A. Wide pH range acceptance minimizes need for adjustment
A. Greater potential for water reuse resulting in zero discharge

Basal Applications
A. Removal of radioactive species, especially in uranium, radium, plutonium
A. Removal of algae
A. Pretreatment for reverse osmosis, ultrafiltration, nanofiltration, etc.
A. Removal of complex organics, especially in fats, grease, fibre, emulsified oils and PAHs
A. Removal of pesticide
A. Treatment of cooling towers water
A. Removal of suspended and colloidal solids
A. Process of multiple contaminants
A. Process of marine bilge waters
A. Process of landfill waters
A. Sludge Dewatering
A. Regeneration of antifreeze
A. Process of commercial laundries waters
A. Process of parking lots waters
A. Process of steam cleaners waters
A. Removal of negatively charged salts such as nitrate, phosphate, fluorides, arsenide, molybdenum, sulphide, chromate, silicate and so on
A. Removal of positively charged heavy metals such as copper, cadmium, nickel, lead, antimony, zinc

Company Details

Established in 2009, JP Water Power Co.,Ltd. has made a name for itself in the list of top suppliers of Water Treatment Plants in India. The supplier company is located in Shenzhen, Guangdong, and is one of the leading sellers of listed products.
JP Water Power Co.,Ltd. is listed in Trade India's list of verified sellers offering supreme quality of High Performance Electrocoagulation Unit, etc. Buy Water Treatment Plants in bulk from us for the best quality products and service.

Business Type

Exporter, Manufacturer

Employee Count

102

Establishment

2009

Working Days

To

Related Products

Explore Related Categories

More Products From This Seller

Seller Details

Shenzhen, Guangdong

Name

Mr. Ketten Xue

Address

No.702, Baoyuan Building, Baoyuan Road., Baoan District, Shenzhen, Guangdong, 518102, China

water treatment equipment in Shenzhen

Report incorrect details

Compare With Similar Products

Buyer Feedback

3

Price Or Price Range

USD2500-48000 USD ($) (Approx.)

400000.00 INR (Approx.)

Minimum Order Quantity

1 Set/Sets

1 Unit/Units, Unit/Units, Unit/Units

Voltage

100 Volt (v)

220-240 Volt (v)

Product Type

EC

Plate Pack Distribution Unit

Payment Terms

Paypal, Western Union, Telegraphic Transfer (T/T)

Cash Advance (CA), Telegraphic Transfer (T/T), Cash in Advance (CID), Cheque

Supply Ability

10 Per Month

1 Per Week

Delivery Time

20 Days

4-6 Week

Main Export Market(s)

Australia, Middle East, South America, Asia, North America

Australia, Middle East, Central America, Eastern Europe, South America, Western Europe, Asia, North America, Africa

Main Domestic Market

All India

All India

People Also Viewed