Carbon Monoxide And Nitrogen Dioxide Gas Transmitter
Price:
Get Latest Price
Minimum Order Quantity :
1
In Stock
Product Specifications
Type | Gas Transmitter |
Payment Terms | Cash Against Delivery (CAD), Cash on Delivery (COD), Cash in Advance (CID), Cheque, Cash Advance (CA) |
Supply Ability | As Per Requirement Per Day |
Delivery Time | 4-7 Days Days |
Sample Available | Yes |
Sample Policy | Contact us for information regarding our sample policy |
Product Overview
Key Features
Product Details:
Range:CO 0 to 500 PPM, NO2 10 PPM.
Output Drift:5% per year in air.
Coverage Area:5000 to 7500 sq ft typical.
Accuracy:CO 2% FS, NO2 3% FS, at the time of calibration.
Storage Temperature:0 to 20 Degree C
Humidity:15 to 90% RH constant; 0 to 99% RH intermittent.
Power Requirement:10 to 36 VDC or isolated 21.6 to 33 VAC.
Enclosure Rating:IP64
Weight:1 lb (0.45 kg).
Brand:Dwyer
Operating Temperature:-20 to 50 Degree C
Resolution:CO 1 PPM, NO2 0.1 PPM.
Response Time:45 s to 90% CO, 25 s to 90% NO2.
Model Available:
Model:Description
GSTC-C:Carbon Monoxide Transmitter with BACnet & Modbus Communication
GSTC-N:Nitrogen Dioxide Transmitter with BACnet & Modbus Communication
GSTC-C-LCD:Carbon Monoxide Transmitter with BACnet & Modbus Communication with Integral LCD Display
GSTC-N-LCD:Nitrogen Dioxide Transmitter with BACnet & Modbus Communication with Integral LCD Display
The Series GSTC Carbon Monoxide/nitrogen Dioxide Gas Transmitter monitors the gas concentration in underground parking garages and loading docks. The carbon monoxide transmitter is used to measure the exhaust of gasoline engines, while the nitrogen dioxide transmitter is used for diesel engines. The Series GSTC is compatible with either BACnet or Modbus communication protocol, allowing the transmitter to be used with almost any building management controller. The GSTC output is communicated over an RS-485 wire via BACnet or Modbus communication protocol. To maximize the accuracy of the Series GSTC, the sensor can be field-calibrated using the A-449 remote LCD display. When the sensor reaches the end of its life, the display will indicate that the sensor needs to be replaced. BACnet and Modbus communication protocol recommend limiting the number of nodes in any segment to 32. Therefore, the transceiver may be rated at one unit load. Fractional loads are also acceptable. The Series GSTC accounts as an eighth of a load on the MS/TP network.
Features:
Industrial grade replaceable CO or NO2 sensors
Field selectable BACnet or Modbus communication on GSTC models
Integral LCD display option
Service display tool for set-up and calibration of models without a LCD
Applications:
Parking Garages
Loading Docks
Mechanical Room Monitoring
Technical Specification:
Sensor:Field replaceable electrochemical, 4 years typical lifespan.
Span and Zero Adjustment:Via pushbutton, using optional A-449 display. Zero only via BACnet or MODBUS communication protocol.
HousingUV resistant glass filled polycarbonate.
Output SignalsBACnet MS/TP, MODBUS RTU, or MODBUS ASCII (switch selectable) communication protocol.
lectrical Connection:Removable terminal block, knock outs for conduit fitting.
Calibration:Via pushbuttons using A-449 auxiliary display. Span gas concentration is field selectable.
Company Details
Focusing on a customer-centric approach, Integrated Engineers has a pan-India presence and caters to a huge consumer base throughout the country. Buy Leak Testing Equipment in bulk from Integrated Engineers at Trade India quality-assured products.
Business Type
Manufacturer, Supplier
Working Days
Monday To Sunday
Related Products
Explore Related Categories
Seller Details
Bengaluru, Karnataka
C.E.O.
Mr. B. Govindraj
Address
Plot No. 15/2, 2nd Floor, Shamanna Compound, M S Complex, Magadi Main Road, Opp. Tollgate Bus stop, Bengaluru, Karnataka, 560023, India
carbon monoxide detector in Bengaluru
Report incorrect details