Diesel Generator Set Features: Latest Technology Product With Global Cummins PlatformEnvironment Friendly PowerLowest Operating Cost And Comprehensive WarrantySingle Source Power Assurance Specifications: Generator Set Specification Model C140D5P C160D5P Duty Prime Prime Power Rating kVA / kWe 140/112 160/128 No. of Phases 3 3 Output Voltage and Frequency (V and Hz) 415 V, 50 Hz 415 V, 50 Hz Power Factor 0.8 (lagging) 0.8 (lagging) Current (A) 195 223 RPM 1500 1500 Engine Specification: Make Cummins Cummins Model QSB5.9-G1 QSB5.9-G2 MoEF Certified Power (hp) 184 206 Required Power for Rated kVA (hp) 174 197 Cooling Liquid Cooled (EG Compleat 50:50) Liquid Cooled (EG Compleat 50:50) Aspiration Turbocharged, Charge Air Cooled Turbocharged, Charge Air Cooled No. of cylinders 6, In-line 6, In-line Bore (mm) x Stroke (mm) 102 x 120 102 x 120 Compression ratio 16.5:1 16.5:1 Displacement (litre) 5.88 5.88 Fuel High Speed Diesel High Speed Diesel Fuel consumption @75% load with radiator and fan* (litre/hr) 26.07 30.05 Fuel consumption @100% load with radiator and fan* (litre/hr) 32.15 36.4 Performance class of generator set ISO 8528-5 G2 ISO 8528-5 G2 Starting system 24 V DC Electrical 24 V DC Electrical Lube oil specification CI4+ 15W40 CI4+ 15W40 Lube oil sump capacity, High-Low level (litre) 14.2- 12.3 14.2- 12.3 Total lubrication system capacity (litre) 15.7 15.7 Lube oil consumption @ full load** (litre/hr 0.02 0.02 Total coolant capacity (litre) 25.6 25.6 Exhaust pipe size (inch) 4 4 Total wet weight (Engine+Radiator)## (kg) 552 552 Length x Width x Height (Engine) (mm) 1066 x 642 x 1029 1066 x 642 x 1029 Mean piston speed (m/s) 5.9 5.9 Combustion air intake @100% load (5%) (cfm) 382 400 Exhaust Temperature (C) 496 522 Alternator Specification: Make Stamford (CGT) Stamford (CGT) Alternator Frame UCI274E UCI274F Enclosure IP 23 IP 23 Voltage regulation (Max.) 1% 1% Class of Insulation H Class H class Winding Pitch 2/3 Pitch 2/3 Pitch Stator Winding Double layer lap Double layer lap Rotor Dynamically Balanced Dynamically Balanced Waveform distortion/ Total Harmonic Distortion No load < 1.5 %, Non distorting balanced linear load < 5 % No load < 1.5 %, Non distorting balanced linear load < 5 % Maximum Unbalanced Load across phases# Less than or equal to 25% less than or equal to 25% Telephonic Harmonic factor < 2% < 2% * Fuel consumption data is based on diesel having specific gravity of 0.85 and conforming to IS:1460. Fuel consumption tolerance is +5%** Oil consumption data is based on oil having specific gravity of 0.89 and meeting CH4 API categories# With the condition that none of the phases exceeds its rated current Dimensions Genset Model Rating (kVA) Length (mm) Width (mm) Height (mm) Wet Weight## (kg) Standard Fuel tank Capacity (litre) C140D5P 140 4000 1150 1850 2565 330 C160D5P 160 4000 1150 1850 2603 330