Diesel Generator Set Specifications: Generator set specification Model C35D5P C40D5P Duty Prime Prime Power Rating kVA / kWe 35/28 40/32 No. of Phases 3 Phase 1 Phase 3 Phase 1 Phase Output Voltage (V) 415 230 415 230 Power Factor 0.8 (lagging)1 0.8 (lagging) 1 Current (3 phase/ 1 phase) (A) 49 152 56 174 Frequency (Hz) and RPM 50 Hz, 1500 RPM 50 Hz, 1500 RPM Engine Specification Make Cummins Cummins Model X3.6TAA-G1 X3.6TAA-G2 MoEF Certified Power (hp) 53 56 Required Power for Rated kVA (hp) 45 51 Cooling Liquid Cooled (EG Compleat 50:50) Liquid Cooled (EG Compleat 50:50) Aspiration Turbocharged, Charge Air cooled Turbocharged, Charge Air cooled No. of cylinders 4, In-line 4, In-line Bore (mm) x Stroke (mm) 95 x 127 95 x 127 Compression ratio 18.3:1 18.3:1 Displacement (litre) 3.6 3.6 Fuel High Speed Diesel High Speed Diesel Fuel consumption @75% load with radiator and fan* (litre/hr) 6.52 7.67 Fuel consumption @100% load with radiator and fan* (litre/hr) 8.69 9.53 Performance class of generator set ISO 8528-5 G2 ISO 8528-5 G2 Starting system 12 V DC Electrical 12 V DC Electrical Lube oil specification CH4 15W40 CH4 15W40 Lube oil sump capacity, High-Low level (litre) 6.5 5 6.5 - 5 Total lubrication system capacity (litre) 7.5 7.5 Lube oil consumption @ full load** (litre/hr) 0.01 0.01 Total coolant capacity (litre) 13 13 Exhaust pipe size (inch) 3 3 Total wet weight (Engine+Radiator)## (kg) 406 406 Length x Width x Height (Engine) (mm) 832 x 525 x 820 832 x 525 x 820 Mean piston speed (m/s) 6.35 6.35 Combustion air intake @100% load (5%) (cfm) 99 114 Exhaust Temperature (C) 400 408 Alternator Specification Make Stamford (CGT) Stamford (CGT) Alternator frame PT144M PI144 J PT144J PI144 K Enclosure IP23 IP23 Voltage regulation (Max.) 1% 1% Class of Insulation H Class H Class Winding Pitch 2/3 2/3 Stator Winding Double layer lap Double layer lap Rotor Dynamically Balanced Dynamically Balanced Waveform distortion/ Total Harmonic Distortion No load < 1.5 %, Non distorting balanced linear load < 5 % No load < 1.5 %, Non distorting balanced linear load < 5 % Maximum Unbalanced Load across phases# Less than or equal to 25% less than or equal to 25% Telephonic Harmonic factor < 2% < 2% * Fuel consumption data is based on diesel having specific gravity of 0.85 and conforming to IS:1460. Fuel consumption tolerance is +5% ** Oil consumption data is based on oil having specific gravity of 0.89 and meeting CH4 API categories # With the condition that none of the phases exceeds its rated current Dimensions Genset Model Rating (kVA) Length (mm) Width (mm) Height (mm) Wet Weight## (kg) Standard Fuel tank Capacity (litre) C35D5P 35 2800 1150 1450 1570 110 C40D5P 40 2800 1150 1450 1570 110