Tryple Trypsin Elisa Kit - 96 Wells, Sandwich Assay, 0.1ng/ml Detection Limit | High Sensitivity, Good Specificity, Stable Results
Price:
Get Latest Price
In Stock
Product Specifications
| Assay type | ELISA |
| Detection limit | 0.1ng/ml |
| Detection method | Sandwich |
| Features | High sensitivity, Good specificity, Stable results, Easy usage, Quantitative assay |
| Format | 96 wells |
| Sample type | TrypLE trypsin |
| Storage | -20°C |
| Usage | TrypLE trypsin detection in samples |
Product Overview
Key Features
The kit uses anti TrypLE trypsin antibody as the coating antibody, the enzyme labeled anti TrypLE trypsin antibody as the detection antibody, the highly sensitive TMB as the substrate, and the TrypLE trypsin as the standard to quantitatively detect TrypLE trypsin in the sample. This kit is characterized by good specificity, high sensitivity and stability,
The lowest detectable level of TrypLE trypsin is 0.1ng/ml.
Principle
This kit uses double antibody sandwich method to detect TrypLE trypsin residuals. The TrypLE trypsin antibody is coated on the microplate, and the TrypLE trypsin in the sample or standard is combined with the antibody fixed on the microplate. After the unconjugated sample or standard is washed with washing solution, the HRP-labeled TrypLE trypsin antibody is added for incubation, and the enzyme labeled antibody is combined with TrypLE trypsin. Wash the unconjugated enzyme labeled antibody, add TMB substrate solution to the microplate, incubate it in dark to form a blue complex, stop the reaction with stop solution, and the color changes from blue to yellow. Determine the absorbance value of the complex, and fit the standard curve with the OD value of the standard. The TrypLE trypsin concentration of the sample can be calculated from the OD value of the sample through the formula fitted with the standard curve.
Kit components
ComponentsQTYPackage
Anti- TrypLE trypsin antibody coated microtiter plate12 strips96T
TrypLE trypsin STD5 vials1ml/vial
TrypLE trypsin reference1 vials1ml/vial
Sample dilution buffer1 bottle10ml/bottle
HRP-labeled antibodyi 100Xi 1 vial100I l/vial
HRP-labeled antibody dilution buffer1 bottle10ml/bottle
Substrate solution1 bottle10ml/bottle
Stop solution1 bottle10ml/bottle
Wash buffer concentratei 20Xi 2 bottle25ml/bottle
COA1 copy
Manual1 copy
Specificity
Control absi NSBi <0.300
3.2ng/ml std abs >0.700
Precisioni %CV average<9.0%
Detection limit (>control 3SD) <0.1ng/ml
Storage and stability
Antibody-coated plate, HRP labeled antibody and TrypLE trypsin standards are stored at -20a , other components are stored at 2-8a . It is stable for 6 months.
Catalog #
TE-19-007
The lowest detectable level of TrypLE trypsin is 0.1ng/ml.
Principle
This kit uses double antibody sandwich method to detect TrypLE trypsin residuals. The TrypLE trypsin antibody is coated on the microplate, and the TrypLE trypsin in the sample or standard is combined with the antibody fixed on the microplate. After the unconjugated sample or standard is washed with washing solution, the HRP-labeled TrypLE trypsin antibody is added for incubation, and the enzyme labeled antibody is combined with TrypLE trypsin. Wash the unconjugated enzyme labeled antibody, add TMB substrate solution to the microplate, incubate it in dark to form a blue complex, stop the reaction with stop solution, and the color changes from blue to yellow. Determine the absorbance value of the complex, and fit the standard curve with the OD value of the standard. The TrypLE trypsin concentration of the sample can be calculated from the OD value of the sample through the formula fitted with the standard curve.
Kit components
ComponentsQTYPackage
Anti- TrypLE trypsin antibody coated microtiter plate12 strips96T
TrypLE trypsin STD5 vials1ml/vial
TrypLE trypsin reference1 vials1ml/vial
Sample dilution buffer1 bottle10ml/bottle
HRP-labeled antibodyi 100Xi 1 vial100I l/vial
HRP-labeled antibody dilution buffer1 bottle10ml/bottle
Substrate solution1 bottle10ml/bottle
Stop solution1 bottle10ml/bottle
Wash buffer concentratei 20Xi 2 bottle25ml/bottle
COA1 copy
Manual1 copy
Specificity
Control absi NSBi <0.300
3.2ng/ml std abs >0.700
Precisioni %CV average<9.0%
Detection limit (>control 3SD) <0.1ng/ml
Storage and stability
Antibody-coated plate, HRP labeled antibody and TrypLE trypsin standards are stored at -20a , other components are stored at 2-8a . It is stable for 6 months.
Catalog #
TE-19-007
Company Details
Established in 2009, HANGZHOU JUNFENG BIOENGINEERING CO. LTD has made a name for itself in the list of top suppliers of Scientific Instruments in India. The supplier company is located in Hangzhou, Zhejiang, and is one of the leading sellers of listed products.
HANGZHOU JUNFENG BIOENGINEERING CO. LTD is listed in Trade India's list of verified sellers offering supreme quality of BSA ELISA Kit, Benzonase ELISA Kit, Enterokinase ELISA Kit, etc. Buy Scientific Instruments in bulk from us for the best quality products and service.
HANGZHOU JUNFENG BIOENGINEERING CO. LTD is listed in Trade India's list of verified sellers offering supreme quality of BSA ELISA Kit, Benzonase ELISA Kit, Enterokinase ELISA Kit, etc. Buy Scientific Instruments in bulk from us for the best quality products and service.
Business Type
Exporter, Manufacturer, Distributor, Supplier, Trading Company
Employee Count
100
Establishment
2009
Working Days
To
Related Products
Explore Related Categories
More Products From This Seller
Seller Details
Hangzhou, Zhejiang
Export Manager
Mr. Guoan Liu
Address
Liuxia Industry Park 11, North Liuhe Road, Xihu District, Hangzhou, Zhejiang, 310022, China
Report incorrect details