We are offering wide range of Line Interactive UPS System of different configurations. It is very user friendly and is made using latest technology. It is Micro controller based intelligent system. 1KVA Model Battery Nos. Recommended Load Back Up time (On recommended load) SW100IB 12V 7 Ah 4 2 PCS (Std Config.) +CFL lights (2X30W) and 1 Fan Load 20 - 30 Min. SW100EB1 12V 26 Ah 2 2 PCs with LCD Monitors +CFL lights (2X30W) and 1 Fan Load ~ 60 Min. SW100 EB2 12V 42 Ah 2 2 PCs with LCD Monitors +CFL lights (2X30W) and 1 Fan Load ~ 2 Hrs. 1500 VA Model Battery Nos. Recommended Load Back Up time (On recommended load) SW150EB1 12V 42 Ah 2 4 PCs (Std. config.) +CFL lights (4X30W) and 1 Fan Load ~ 30 Min. SW150EB1 12V 65 Ah 2 4 PCs (Std. config.) +CFL lights (4X30W) and 1 Fan Load ~ 1 Hr. SW150E10 12V 100 Ah 2 3 PCs (Std. config.) +CFL lights (4X30W) and 1 Fan Load ~ 2 Hrs. 2000 VA Model Battery Nos. Recommended Load Back Up time (On recommended load) SW250EB1 12V 42 Ah 4 4 PCs (Std. Config.) +CFL lights (4X30W) and 2 Fan Load 60 Min. SW200EB2 12V 65 Ah 4 4 PCs (Std. Config.) +CFL lights (4X30W) and 2 Fan Load ~ 90 Min. SW250EB3 12V 100Ah 4 4 PCs (Std. Config.) +CFL lights (4X30W) and 2 Fan Load ~ 2 Hrs. Applications: Small Computer NetworksHome ComputersSmall OfficesRetail showrooms Salient Features Line Interactive- Ultra fast switching due to synchronized transfer from mains to Inverter and Inverter to Mains.Pure Sine Wave output makes it universally acceptable for all types of loads, including motorised machines like ATMs. Microprocessor Based, reduces component count to increase reliability, simplify servicing.Wide Input Voltage Range, ensures UPS runs on mains voltage even at low input voltage without discharging batteries.Short Circuit, Over Load protection provides capability to withstand fluctuating load and accidental short circuit in power line.Battery Deep discharge protection, Off-Mode charging and "Advanced Battery Management" program to enhance life of battery.EMI/RFI/Lightning/SURGE and Spike protection.Serial communication port / SNMP (Optional) to enable monitor and control through web. Key Technical Specifications Mains Voltage 220 V - 1 Ph, Input power factor 0.98 (mains Mode) Voltage range 150 to 270 V Frequency Range 46 to 54 Hz Output Voltage 220 V +/- 8% Pure Sine Wave. Dynamic Voltage for 0-100% Load change +/- 2% max. Frequency Precision (on Inverter) 0.2% Crest Factor 3: 1 Overload Capacity upto 110 % For continuous. > 110% Overload alarm and shutdown. Auto-recovery on removal of overload. Efficiency (Mains)(Inverter) >96 % (full Load) ~80 %