Product Specifications

ColorDark Blue
Power Range0.75 to 55kW
Voltage380 to 480V
EnclosureNEMA 1
CommunicationModbus, Profibus
Safety StandardsUL508
Design Life10 years
FeaturesEasy installation, Pump protection, Fan belt detection, Energy saving, PID control, Stable temperature, Fresh air, Ideal humidity

Product Overview

Key Features




Based in Mumbai,
India, we are a top most manufacturer, supplier and exporter of HVAC Drives. Offer stability
and comfortable temperature in the living spaces, these drives are widely used in pumping, ventilation,
water distribution, blower, agitators and cooling tower. Designed and developed
by using superior grade components and advanced technology, our HVAC Drives give assurance to provide
fresh & filtered air and maintain an ideal humidity level.



Features



  • Pump dry run protection
  • Broken fan belt detection
  • Easy to install




HVAC Drives

We are involved in offering HVAC Drives. These are highly applauded in the market for offering stability comfortable temperature in the living spaces. Our high quality range guarantees to provide fresh and filtered air and maintain an ideal humidity level.

  • A new control system that minimizes the power consumed by the drive itself (drive loss) as well as the power loss in the motor
  • Equipped with full function PID
  • Optimum functions for HVAC
  • Pump dry run protection
  • Broken fan belt detection
  • Universal I/Os, freely configurable to be used with PLC / BMS / PC
  • Display can be configured for various physical parameters like Flow rate, Pressure, Temperature
  • Power monitoring, Power (kW), Cumulative power (kWh), Cumulative power rates (Rs/kWh)
  • Information related to equipment maintenance is displayed
  • Multiple pump and fan sequencing software in-built
  • NEMA1 Enclosure
  • Communication cards for Lonworks, Profibus, Modbus plus, CC link, N2, Backnet
  • The design life of components- 10 years

Specially Designed for

  • Pumping
  • Ventilation
  • Water distribution
  • Blower
  • Agitators
  • Cooling tower

Three-Phase 400V Series - 0.75 to 55kW

Item

Specifications

Type (FRN-F1S-4A)

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

Nominal applied motor (kW) *1

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

Output Rating

Rated capacity (kVA) *2

1.9

2.8

4.1

6.8

9.5

12

17

22

28

33

44

54

64

77

Rated voltage (V) *3

Three-phase, 380 to 480V (with AVR function)

Rated current (A) *4

2.5

3.7

5.5

9

12.5

16.5

23

30

37

44

59

72

85

105

Overload capability

120% of rated current for 1min

Rated frequency

50, 60Hz

Input
Rating

Phases,
voltage,
frequency

Main power supply

Three-phase, 380 to 480V, 50/60Hz

Three-phase, 380 to 440V/50Hz
Three-phase, 380 to 480V/60Hz

Auxiliary control
power input

Single-phase, 380 to 480V, 50/60Hz

Single-phase, 380 to 440V/50Hz
Single-phase, 380 to 480V/60Hz

Auxiliary fan power input *9

-

*10

Voltage/frequency allowance

Voltage: +10 to -15% (Voltage unbalance: 2% or less) *8, Frequency: +5 to -5%

Rated current (A) *5

(with DCR)

1.6

3

4.5

7.5

10.6

14.4

21.1

28.8

35.5

42.2

57.0

68.5

83.2

102

(without DCR)

3.1

5.9

8.2

13.0

17.3

23.2

33.0

43.8

52.3

60.6

77.9

94.3

114

140

Required power supply capacity (kVA) *6

1.2

2.2

3.1

5.3

7.4

10

15

20

25

30

40

48

58

71

Braking

Torque (%) *7

20

10 to 15

DC injection braking

Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60%

DC reactor (DCR)

Option

Applicable safety standards

UL508C, C22.2 No.14, EN50178:1997 (Applying)

Enclosure (IEC60529)

UL508C, C22.2 No.14, EN50178:1997 (Applying)
IP20, UL open type

IP00, UL open type

Cooling method

Natural cooling

Fan cooling

Mass (kg)

3.1

3.2

3.3

3.4

5.8

6.0

6.9

3.4

9.4

9.9

11.5

23

24

33

Three-Phase 400V Series - 75 to 560kW

Item

Specifications

Type (FRN-F1S-4A)

75

90

110

132

160

200

220

280

315

355

400

450

500

560

Nominal applied motor (kW)

75

90

110

132

160

200

220

280

315

355

400

450

500

560

Output Rating

Rated capacity (kVA) *2

105

128

154

182

221

274

316

396

445

495

584

640

731

792

Rated voltage (V) *3

Three-phase, 380 to 480V (with AVR function)

Rated current (A) *4

139

168

203

240

290

360

415

520

585

650

740

840

960

1040

Overload capability

120% of rated current for 1min

Rated frequency

50, 60Hz

Input Rating

Phases, voltage, frequency

Main power supply

Three-phase, 380 to 440V, 50Hz or Three-phase, 380 to 480V, 60Hz

Auxiliary control power input

Single-phase, 380 to 480V, 50/60Hz

Auxiliary fan power input *9

Single-phase, 380 to 440V/50Hz Single-phase, 380 to 480V/60Hz

Voltage/frequency variations

Voltage: +10 to -15% (Voltage unbalance: 2% or less) *8, Frequency: +5 to -5%

Rated current (A) *5

(with DCR)

138

164

201

238

286

357

390

500

559

628

705

789

881

990

(without DCR)















Required power supply capacity (kVA) *6

96

114

140

165

199

248

271

347

388

435

489

547

611

686

Braking

Torque (%) *7

10 to 15

DC injection braking

Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60%

DC reactor (DCR)

Option

Applicable safety standards

UL508C, C22.2 No.14, EN50178:1997 (Applying)

Enclosure (IEC60529)

IP20, UL open type

Cooling method

Fan cooling

Mass (kg)

34

42

45

63

67

96

98

162

165

282

286

355

360

360

  • (1) Fuji's 4-pole standard motor
  • (2) Rated capacity is calculated by assuming the output rated voltage as 440V for three-phase 400 V series
  • (3) Output voltage cannot exceed the power supply voltage
  • (4) An excessively low setting of the carrier frequency may result in the higher motor temperature or tripping of the inverter by its over current limiter setting. Lower the continuous load or maximum load instead. (When setting the carrier frequency (F26) to 1kHz, reduce the load to 80% of its rating.)
  • (5) Trial calculation done on assumption that the power capacity is 500kVA (or 10 times the inverter capacity if the inverter capacity is larger than 50kVA) and the inverter is connected to the power supply of %X=5%
  • (6) Obtained when a DC reactor (DCR) is used
  • (7) Average braking torque (Varies with the efficiency of the motor)
  • (8) Voltage unbalance (%) = ( MAX. voltage(V) - Min. voltage(V) ) / ( Three-phase average voltage(V) ) x 67 (IEC61800-3)
  • If this value is 2 to 3%, use an AC reactor (ACR option)
  • (9) Use [R1, T1] terminals for driving AC cooling fans of an inverter powered by the DC link bus, such as by a high power factor PWM converter. (In ordinary operation, the terminals are not used)
  • (10) Single-phase, 380 to 440V/50Hz or Single-phase, 380 to 480V/60Hz



Company Details

SPRINT CONTROLS, Established in 1998 at Mumbai in Maharashtra, is a leading service provider of Industrial Automation in India. SPRINT CONTROLS is one of Trade India's verified and trusted names for listed services. With extensive experience in the field of Industrial Automation, SPRINT CONTROLS has made a reputed name for itself in the market with satisfactory AC Servo System, Electrical Automation Encoders, Faldic Alpha 5 Smart, etc.
Focusing on a customer-centric approach, SPRINT CONTROLS has a pan-India presence and caters to a huge consumer base throughout the country. Get Industrial Automation from SPRINT CONTROLS at Trade India quality-assured services.

Business Type

Exporter, Importer, Manufacturer, Service Provider, Distributor, Supplier, Trading Company

Employee Count

45

Establishment

1998

Related Products

Explore Related Categories

More Products From This Seller

Seller Details

Mumbai, Maharashtra

Proprietor

Mr. Vaibhav Chokhawala

Address

K-121, Ansa Industrial Esate, Sakivihar Road, Andheri (E), Mumbai, Maharashtra, 400072, India

ac drives in Mumbai

Report incorrect details

Compare With Similar Products

People Also Viewed