Multifunction Process Calibrator / Temperature Calibrator - VISMA 700 Quick Details Source : 20V, 24mA, 4000 ohm, Loop 24V Measure : 30V, 24mA, 4000 ohm Operating Temperature: -10 C to 55 C Accuracy Class: 0.025% Measuring Range: 30V, 24mA, 4000 ohm Dimensions: 224 x 172 x 65 mm Weight: 1.2kg Supply Voltage: 9.6V Packing : Metal Carry case Product Information Features A split-screen display. The upper display allows users to measure volts, and current. The Lower display allows users to measure and source Volts, Current, Resistance Temperature Detectors (RTD), Thermocouples and Ohms. A thermocouple (TC) input / output terminal with cold junction temperature compensation, and ambient temperature can be set and calibrate within the menu function.Each parameter can manual and automatic stepping and ramping output, signal output can be arbitrarily set within the 0% and 100% of the value.Power off time for Instrument, Backlight off time, Screen Contrast, Cold junction compensation ON/OFF, HART resistance ON/OFF and ETC can be set manually In the configuration menu.Calendar & clock functionIt can store 8 measurement and output data, all the settings and the functions of the last operation can be auto-stored after power off.Large capacity rechargeable battery with power adapter, integrated charge-management functionsDigital keys make the operation more simple.The meter provide 24V voltage outputAccuracy:0.025% SpecificationsSignal Generation outputFunctionRangeResolutionAccuracy, (% of Reading + Counts)Current Sourcing0 to 24.000mA0.001mA0.02% + 4 Voltage Sourcing0 to 20.000V0.001V0.02% + 30 to 90.000mV0.001mV0.01% + 10 Resistance Sourcing5.00 Ohm to 400.00 Ohm0.01 Ohm0.05 Ohm400.00 Ohm to 1500.00 Ohm0.1 Ohm0.5 Ohm1500.00 Ohm to 4000.00 Ohm0.1 Ohm1 Ohm Loop Power SupplyFunctionRangeAccuracy,Max. currentLoop Power Supply24VN/A22mAMeasurementFunctionRangeResolution (% of Reading + Counts)Current Measurement0 to 24.000mA0.001mA0.02% + 4 Voltage Measurement0 to 30.000V(Upper Display)0.001V0.02% + 30 to 24.000V(Lower Display)0.001V0.02% + 30 to 90.000mV0.001mV0.01% + 10Resistance measurement0 to 400.00 Ohm0.1 Ohm0.15 Ohm400.00 Ohm to 4000.00 Ohm0.5 Ohm1 Ohm RTD and Thermocouple: Type Measure Accuracy Output Accuracy PT-100 (385) 0.3 C(4 wire ) , 0.5 C(2 wire and 3 wire) 0.3 C PT-100 (3926) 0.3 C(4 wire ) , 0.5 C(2 wire and 3 wire) 0.3 C PT-100 (JIS) 0.3 C(4 wire ) , 0.5 C(2 wire and 3 wire) 0.3 C PT-200 (385) 0.8 C(4 wire ) , 1.6 C(2 wire and 3 wire) 0.8 C PT-500 (385) 0.4 C(4 wire ) , 0.9 C(2 wire and 3 wire) 0.4 C PT-1000 (385) 0.2 C(4 wire ) , 0.3 C(2 wire and 3 wire) 0.3 C Cu50 0.4 C (4 wire ) , 0.6 C(2 wire and 3 wire) 0.4 C Cu100 0.4 C (4 wire ) , 0.6 C(2 wire and 3 wire) 0.4 C J: 0.5 C 0.7 C K: 0.8 C 0.8 C T: 0.5 C 0.5 C E: 0.5 C 0.5 C R: 1.5 C 1.0 C S: 1.5 C 1.5 C B: 1.8 C 1.0 C N: 0.8C 0.8 C Accesories1. Tester leads (red and black)2. Bending test plug wire clip (red and black)3. Instruction Manual4. Adapter 5. Metal Carry case6. Spare fuse 7. 1.2V x 8 Ni-MH rechargeable batteries