voice searchcamera search
Le Chatelier Mould Mtct-13 - Brass Split Cylinder Cement Testing Equipment | Humidity 65 ± 5 %, Temperature 27 ± 2 °C, Measures Volume Expansion

Le Chatelier Mould Mtct-13 - Brass Split Cylinder Cement Testing Equipment | Humidity 65 ± 5 %, Temperature 27 ± 2 °C, Measures Volume Expansion

Get Latest Price

Minimum Order Quantity :

1 Piece

Brand Name :

Teknik

In Stock

In Stock

Product Specifications

Equipment TypeLE Chatelier Mould
Response TimeInstantaneous on manual measurement
AccuracyStandard as per IS 4031
HumidityHumidity 65 A+- 5 %
Automation GradeManual
FeaturesBrass/metallic split mould with indicating arms, supplied with glass plate and weights
Mounting TypeBench-top
Product TypeLE Chatelier Mould
UsageCement Testing Equipment
Specimen SizeMould internal diameter 30 mm A-- height 30 mm
Max HeightApprox. 30 mm
Number of Specimens1
TemperatureTemperature 27 A+- 2 AdegC
ApplicationCement Testing Equipment
CapacitySingle test
Machine WeightApprox. 150 g
Control ModeManual
Sample AvailableYes
Sample PolicySample costs shipping and taxes has to be paid by the buyer
Packaging Detailscarton box, export quality also available
Main Export Market(s)Asia, Middle East, Africa
Main Domestic MarketAll India
CertificationsISO 9001, 14001 ,CE

Product Overview

Key Features

LE Chatelier Mould MTCT-13

Cement of good quality does not contain the impurities like free lime, magnesia and sulphates, so this should be checked before use. When it contains the impurities named above, it can expand after reacted with the water, which will result in the unwanted results like, cracking, unwanted expansion of the dimensions and lower strength. Prepare a cement paste of 78% of standard consistency of the cement, and fill it into the split brass cylinder. Cover the top and bottom of the cylinder and put it in water at 27 degrees Celsius for 24 hours. After 24 hours, measure the separation between the two indicators at their pointed ends. Then heat the whole water and immersed cylinder with paste up to a boiling temperature in 30-35 minutes and then boiling for 3 hours. After cooling it down, again measure the separation between the two pointers.

Technical Specification
Temperature 27 2 C
Humidity 65 5 %
Volume expansion in cement mortar or in cement concrete is caused by the presence of UN burnt lime (CaO), dead burnt MgO and also CaSO4.
By Le-chatelier method we can only find out presence of un burnt lime (CaO).
Presence of UN burnt lime may develop cracks in the cement because of increase in volume.
Free lime (CaO) and magnesia (MgO) are known to react with water very slowly and increase in volume considerably, which result in cracking, distortion and disintegration
Two parallel demonstrating arms with pointed closures are connected.

Company Details

An ISO 9001-2008, ISO 18001-2007, ISO 14001-2004 certified firm. At M/S MICRO TEKNIK, we have more than five decades of experience in the field of offering Science Instruments for a number of industrial and educational sectors. Our immense array includes Audio Visual Projectors, Surgical Accessories, Clean Air Systems, Working Model Engines, Applied Mechanics and Construction Machine Lab Equipment and many more. Since the time of our incorporation in the year 1967, we have become the most favorable choice of our customers due to our eth

Business Type

Exporter, Manufacturer, Distributor, Supplier, Trading Company

Employee Count

25

Establishment

1973

Working Days

Monday To Saturday

GST NO

06ACMPJ7244B1ZS

Certification

ISO 9001 : 2015

Related Products

Explore Related Categories

More Products From This Seller

Industry Leader

Seller Details

GST

GST - 06ACMPJ7244B1ZS

Trusted SellerTrustedSeller
Super seller

Ambala Cantt, Haryana

CEO

Mr Vikas

Members since

14 Years

Address

Plot No. 73, Vikaspuri, Industrial Area, Ambala Cantt, Haryana, 133001, India

le chatelier mould in Ambala Cantt

Report incorrect details

Compare With Similar Products

Buyer Feedback

3

4

Minimum Order Quantity

1 Piece/Pieces

1 Piece/Pieces

1 Set/Sets

Equipment Type

LE Chatelier Mould

Testing Mould

Response Time

Instantaneous on manual measurement

Immediate

Accuracy

Standard as per IS 4031

As per IS:2696/BS: 6463/ASTM C151

Humidity

Humidity 65 A+- 5 %

Ambient

Automation Grade

Manual

Manual

Features

Brass/metallic split mould with indicating arms, supplied with glass plate and weights

Corrosion resistant, Brass construction, Split ring, Two parallel indicating arms

Mounting Type

Bench-top

Bench/Surface mount

Usage

Cement Testing Equipment

Laboratory (Cement Soundness Test)

Specimen Size

Mould internal diameter 30 mm A-- height 30 mm

Cement paste, 70 mm dia. x 35 mm high ring

Max Height

Approx. 30 mm

35 mm (Specimen Ring Height)

Number Of Specimens

1

1 per mould

Temperature

Temperature 27 A+- 2 AdegC

Room Temperature (Approx. 27C)

Application

Cement Testing Equipment

Determination of soundness (expansion) of cement

Capacity

Single test

Single specimen

Machine Weight

Approx. 150 g

Approx. 500 g

Control Mode

Manual

Manual

Main Domestic Market

All India

All India

Supply Ability

As per Order Per Day

10 Per Month

Delivery Time

As per Order Days

7 Days