Digital PH Tester - Digital Meter | Accuracy: ±0.05 pH Range: 0.00 to 14.00 pH Power Supply: 4 x 1.5V Alkaline Calibration Required
Price: 7.3 USD
Get Latest Price
Minimum Order Quantity :
500
In Stock
Product Specifications
Material | digital meter |
Power Supply | 4 x 1.5V alkaline |
Power Consumption | 4 x 1.5V alkaline Volt (V) |
Accuracy | A+-0.05 pH pH |
Display Type | Digital Only |
Range | 0.00to 14.00 pH |
FOB Port | GUANGZHOU |
Payment Terms | Cash Advance (CA) Telegraphic Transfer (T/T) |
Supply Ability | 100000 Per Month |
Delivery Time | 12 Days |
Sample Policy | If order is confirmed we will reimburse the sample cost |
Packaging Details | 40*40*38CM/ctn |
Main Export Market(s) | Asia Australia Eastern Europe Western Europe Africa Central America Middle East South America North America |
Main Domestic Market | All India |
Certifications | CE |
Product Overview
Key Features
OPERATION
a cRemove the protective cap. Do not be alarmed if white crystals appear around the cap. This is normal with pH electrodes and they dissolve when rinsed with water.
a cTurn the tester ON by pressing the 'ON/OFF' button.
a cImmerse into solution up to the max immersion level.
a cStir gently and wait until the display stabilizes.
a cAfter use Turn the tester off by pressing the i ON/OFFi button use the water clean the electrode and replace the protective cap. Do not use distilled or deionized water for storage purposes.
a cLarge fluctuations in readings could be due to lack of calibration dry electrode or rundown batteries.
CALIBRATION
a cImmerse the tester up to the maximum immersion level in pH 6.86 buffer solution.
a cAllow the reading to stabilize and using a small screwdriver adjust the calibration trimmer to read 6.86
a cImmerse the electrode in PH4.01 or PH9.18 the standard buffer solution of borax. Until the display shows i 3.96-4.06PHi ori 9.13-9.23PHi . Always use fresh buffers for calibration.
Important The instrument must be re-calibrated whenever.
a cThe electrode or battery has been replaced.
a cApproximately one mouth has passed from the last calibration.
a cThe electrode has been used in particularly taxing conditions.
Company Details
Business Type
Exporter, Manufacturer, Supplier
Employee Count
100
Establishment
2006
Working Days
Monday To Saturday
Related Products
Explore Related Categories
More Product From This seller
Seller Details
Guangzhou, Guangdong
Manager
Ms Sally Tan
Address
No.1 Ke Sheng Road National High-Tech Development Zone Technology Park Baiyun District Guangzhou Guangdong 510540 China
digital ph meters in Guangzhou
Report incorrect details