
The Maintenance Process
Price:
Get Latest Price
In Stock
Product Specifications
| Material | Vitreous China |
| Cartridge life | 7000 uses |
| Sealant type | Blue liquid |
| Installation | Easy |
| Maintenance | Simple |
| Disposal | Easy |
| Features | Waterless operation, Reduced expenses, Hygienic, Water conservation, Easy maintenance, Long-lasting cartridge, Environmentally friendly |
Product Overview
Key Features
The Maintenance Process
- Clean, Effective & Beneficial
- Our waterfree system provides our users with:
- Touch free operation
- Reduced operating expenses
- Hygienically cleaner than watered urinals
- Ability to conserve a precious resource - water!
- This presentation will guide you through the necessary steps to properly maintain Falcon Waterfree urinals
How the system works
- Vitreous China (Porcelain) urinals
- The cartridge acts as a funnel
- Urine flows down into the cartridge, through blue sealant liquid
- Sediments collect inside the cartridge
- Remaining urine is allowed to pass freely down the drain
- Customers should expect 7000 uses per cartridge
Maintenance is Essential
- The system operates flawlessly when two things are done correctly
- Proper installation
- Proper on going maintenance
- Proper cleaning is essential
Changing Cartridges & Basic Cleaning
Step 1:
Do you have everything needed? The box should have:
- Cartridge (1)
- Plastic key (1)
- Sealant (1)
- Disposal bag (1)
- Plastic glove (1)
- Instructions (1)
step 2
Anticipating Change-out
- Expect 7,000 uses per cartridge
- Estimate the time from install to change:
Observing Spent Cartridge
- Flow of fluids has nearly stopped
- Run small amount of water down cartridge to observe flow rate
- Flow of fluids has stopped
- Trace amounts of blue sealant are visible on the cartridge
- Important: Premature cartridge failure can be the result of several factors. Contact Falcon Customer Experience Department for assistance in troubleshooting causes: Call: 616-975-0174
Removing the cartridge & disposal
Tip: Use mist of aerosol spray to dissipate odors from open trap
- Using the plastic glove, insert plastic key into cartridge
- Turn counterclockwise, from 12 o'clock to the 11 o'clock position
- Once free, lift upward carefully allowing fluids to drain momentarily
- Place cartridge into disposal bag
- Tightly secure top of bag
- Disposal options:
- Recycle
- Ordinary trash
Step 4:
Flushing the drain line
- To ensure a clear, clean drain line always carefully flush the open line with 1-2 buckets of warm soapy water - ensuring the bottom of the housing and line are clean & there's good flow
- This takes just a moment and ensures open drain lines
- Snaking of lines should occur only when lines cannot be opened with simple flushing
- Care must be taken when snaking to avoid damage to the urinal and/or housing
Install new cartridge
Prep:
- Wipe clean the housing rim area
- This helps prevent sticking of cartridges
Installation:
- Using the key provided, lower the cartridge into the housing at the 11 o'clock position
- Turn clockwise to the 12 o'clock position - locking cartridge into the housing
Step 6:
Priming the cartridge
Step One:
- Fill the cartridge with approximately 32 oz of water or until there no air bubbles escaping from the cartridge.
- It's essential to always add water before proceeding to adding sealant!
- Add blue sealant to cartridge
- Allow sealant to drain into the cartridge until only trace amounts remain
Step 7:
Quick clean-up
Clean-up is a snap!
- Using a sponge or soft rag, wipe away traces of blue sealant remaining on the cartridge
- Spray (mist) cleaner onto bowl surface
- Never dump large amounts of any cleaning solution directly into the bowl
- Wipe with sponge, soft rag or Johnny mop.
- That's it!
Critical steps
- Turn counterclockwise, from 12 o' clock to the 11 o' clock position
- Once free, lift upward carefully allowing fluids to drain momentarily
- Always carefully flush the open line with 1-2 buckets of warm soapy water, ensuring the bottom of the housing and line are clean
- Care must be taken when snaking to avoid damage to the urinal and/or housing
- Wipe clean the housing rim area. This helps prevent sticking of cartridges
- Installation of cartridge:
- Using the key provided, lower the cartridge into the housing at the 11 o'clock position
- Turn clockwise to the 12 o' clock position - locking cartridge into the housing
- It's essential to always add water before proceeding to adding sealant!
- Spray (mist) cleaner onto bowl surface
- Never dump large amounts of any cleaning solution directly into the bowl
- Never dump mop buckets into a urinal with a primed cartridge
Shortened Cartridge Life ?
Troubleshooting
Flushing of cartridge
- Cause: Dumping mop buckets into bowl flushes away sealant
- Solution: Janitorial staff training
Breakdown of sealant
- Causes: Cleaners or other chemicals being dumped into the bowl
- Solutions: Get list of cleaner(s) used by janitorial crew Investigate other chemicals Coordinate with FWT Customer Experience Dept
Plugged with foreign materials
- Causes: Entrance of dirt from mop buckets Presence of items forced into cartridge
- Solutions: Work with janitorial staff Consider use of diverters
Cartridge is used up
- Cause: Customer has received 7000 uses but is unaware, feeling that the unit failed prematurely
- Solution: Work with customer to understand the usage- estimate usage patterns
Company Details
Business Type
Exporter, Manufacturer, Supplier
Employee Count
9
Establishment
2018
Working Days
Monday To Sunday
GST NO
27AADFW2825N1ZR
Related Products
More Product From This seller
Seller Details
GST - 27AADFW2825N1ZR
Pune, Maharashtra
Director
Mr. Rajendra Goenka
Members since
1 Years
Address
33/B, Daulatraj Building, Deccan College Rd, Yerawada, Pune, Maharashtra, 411006, India
Sanitaryware in Pune
Report incorrect details























