
Scroll Water Chilling
Price:
Get Latest Price
In Stock
Product Overview
Key Features
Our company is leading the industry with a wide stock of Scroll Water Chilling system. All these types of chillers are engineered from best quality of scroll compressors that are specially procured from the danfoss-maneurop and Copeland. With the capability of sustaining cooling process from temperature ranging from + 20c up to -15c, this Scroll Water Chilling systems have its separate and individual refrigeration circuits.
Features
- Have the capability to reach up to - 50c
- Multiple scroll compressors
- Robust construction
Further Details
These chillers are also rated for an ambient of up to (+) 480c and cooling tower water temperature up to (+) 37c at the inlet of the condenser.
TECHNICAL SPECIFICATIONS
Model No. | Capacity (k cal/hr) | Flow Rate (liter/mins) | Minimum Temp.(C) | Power (kw) |
CC-CH-3 | 9000 | 30 | +6 | 4 |
CC-CH-4.5 | 13500 | 45 | +6 | 6 |
CC-CH-6 | 18000 | 60 | +4 | 8 |
CC-CH-8 | 24300 | 80 | +4 | 10 |
CC-CH-10 | 30000 | 100 | -3 | 13 |
CC-CH-12 | 36600 | 122 | -3 | 15 |
CC-CH-15 | 45000 | 150 | -3 | 19 |
CC-CH-16 | 48600 | 160 | -3 | 20 |
CC-CH-18 | 54300 | 180 | -3 | 23 |
CC-CH-20 | 60000 | 200 | -3 | 26 |
CC-CH-24 | 73500 | 245 | -3 | 32 |
CC-CH-30 | 90000 | 300 | -3 | 39 |
CC-CH-40 | 120000 | 400 | -5 | 52 |
CC-CH-60 | 180000 | 600 | -5 | 75 |
CC-CH-90 | 270000 | 900 | -5 | 110 |
CC-CH-120 | 360000 | 1200 | -5 | 145 |
- Capacities based on 7C evaporating temperature.
- Flow rate Calculated considering a of 5C.
- Power required 415 V 3 phase 50 Hz.
- 10% cooling capacity increase in water cooled system.
- Due to continuous R&D, the above information is subject to change without notice.
CALCULATIONS FOR REQUIRED COOLING ENERGY
First Step for proper selection of Chiller is done by knowing quantity of heat to be dissipated. To find out heat dissipated, use of following formula is made. Heat to be dissipated (KCal/hr) Flow of the liquid (Kg/hr) T(Temp. difference in inlet & outlet of fluid ) (C) Specific heat of the liquid (KCal/Kg XC) | Heat = Kh/hr X Spec. Heat X ( t out - t in) For water and glycol the spec. heat is 1 and 1 Kg is equivalent to 1 liter. Calculation Example for water: Water flow in the circuit 2000 I/hr. t out 25C t in 20 C Heat = 2000 x 1 x (25-20) = 10,000 Cal/hr. 1 TR = 3000 KCal/hr 1 TR = kw x 0.286 |
Company Details
Focusing on a customer-centric approach, COOL COMMAND ENGINEERS has a pan-India presence and caters to a huge consumer base throughout the country. Get Cooling Tower & Chilling Plants from COOL COMMAND ENGINEERS at Trade India quality-assured services.
Business Type
Manufacturer, Service Provider, Supplier
Employee Count
15
Establishment
1995
Working Days
Monday To Sunday
Related Products
Explore Related Categories
More Product From This seller
Seller Details
Noida, Uttar Pradesh
Accepts only Domestic inquiries
Ceo
Mr. Chandra Kant Singh
Address
T-7, Shree Jee Complex, Sharma Market, Harola, Sector 5, Noida, Uttar Pradesh, 201301, India
scroll chiller in Noida
Report incorrect details