
Multipair Cable
Price:
Get Latest Price
In Stock
Product Specifications
| Material | Copper |
| Insulation | PVC |
| Shielding | Aluminum foil |
| Diameter | Variable |
| Length | Customizable |
| Temperature range | 60 deg C |
| Conductor gauge | 40 AWG minimum |
| Features | High strength, Durable design, Superior quality, Low maintenance, Versatile use, Reliable connection, Weather resistant |
Product Overview
Key Features
Our company is counted among the well known manufacturers, exporter, importer and supplier of Multipair Cables which is twisted into pairs, stranded into mini-units. These cables are resistive to harsh weather in characteristics and is used for various connection usages. We provide the complete product range of Multipair Cable in diverse finishing norms and values and can be customized as per the usages area. Apart from that, our professionals use quality assured raw materials and latest technology in order to ensure its strength and long functional life.
A multi-pair shielded cable is a cable made up of a plurality of pairs of insulated wires disposed inside a sleeve of insulating material. Multi-pair shielded cable is used extensively in the communications and computer industries. Cables for high-speed data communications typically consist of multiple twisted pairs.
A twisted pair exchange cable comprises groups of individual conductor wires that are twisted together into pairs. A wide variety of cable arrangements having twisted conductor pairs are utilized in the telecommunication industry. The increased need for high-speed communication transmissions has placed a greater demand on twisted conductor pair systems.
When twisted pairs are closely placed in a cable, electrical energy may be transferred from one twisted pair of a cable to another twisted pair. Such energy transferred between twisted pairs is referred to as crosstalk. As operating frequencies increase, improved crosstalk isolation between the twisted pairs becomes more critical.
The TIA/EIA-568A or TIA/EIA 568B specification sets out transmission requirements, such as, for example, maximum acceptable crosstalk, skew and impedance mismatch values between twisted pairs, for cables that are classified as Category 5 (Cat. 5) and category 6 (Cat. 6) cables. In order to meet these requirements various techniques are employed to control crosstalk between twisted pairs and skew.
Multi-pair cables are used to transfer communication signals between, for example, components of a local area network (LAN) such as computers, telephones, and other devices. With multi-pair cables, the signals generated at one end of the cable should ideally arrive at the same time at the opposite end even if they travel along different twisted pair wires.
Features :
- High tensile strength
- Durable standard
- Superior strength
- Low maintenance requirement
- Subj.758
- Section 2
- Page 2835
- Issued:1976-10-28
- Revised:2013-02-25
- Style2835 Multiple-Conductor Cable Using Extruded Non-Integral et
UL2835 Specification :
| Rating | 60 deg C, 30 Vac, Cable flame for Use No. 1B and 2B, Horizontal flame for Use No. 1A and 2A. | |||
| Conductor | 40 AWG minimum. | |||
| Insulated Conductor | Material not specified for Use No. 1A or 1B. Labeled or complies with manufacturer's Procedure for Use No. 2A or 2B. | |||
| Assembly | Two or more conductors, twisted pairs, or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval, or round cable construction. Lay not specified. Barrier layer and/or fillers optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete description of each assembly. | |||
| Covering | Optional. Extruded PVC, 5 mils minimum thickness at any point, over the assembly or groups of singles. | |||
| Shield | Optional. May be over one or more of the insulated conductors or applied over the assembly. | |||
| Jacket | Extruded PVC. If parallel construction is rippable, the measurements are made after ripping. | |||
| Diameter of cable under etx | Minimum average thickness | Minimum thickness at any point |
| |
| 0.250 inch or less (1A | 2A only) | 15 mils | 13 mils | |
| 0.250 inch or less (1B | 2B only) | 30 mils | 27 mils | |
| 0.251-0.424 inch | 30 mils | 27 mils |
| |
| 0.425-0.700 inch | 60 mils | 48 mils |
| |
| 0.701-1.500 inch | 80 mils | 64 mils |
| |
| 1.501-2.500 inch | 110 mils | 88 mils |
| |
| 2.501 inch or larger | 140 mils | 112 mils |
| |
| Major diameter if flat or oval construction. | ||||
| Standard | Appliance Wiring Material UL 758. | |||
| Marking | General. | |||
| Use | Use No. 1A:, Internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.; Use No. 1B:, CABLES - using 30 mils or greater et thickness only: External interconnection or internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.; Use No. 2A:, Internal wiring in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas.; Use No. 2B:, CABLES - using 30 mils or greater et thickness only: External interconnection or internal wiring in Class 2 circuits | |||
UNDERWRITERS LABORATORIES INC. APPLIANCE WIRING MATERIAL
- Subj. 758
- Section 2 Page
- 20251 Issued: 1983-02-23
- Revised: 2005-08-12
UL20251 Specification :
| Style | 20251 Multi-Conductor Cord. |
| Rating | 60C, 150 Volts, 300 Volts peak. |
| Conductor | Two to ten 18-33 AWG, tinned or bare, solid, stranded, or tinsel. May include mixed AWG sizes. |
| Insulation | Polypropylene, 7 mils minimum average, 5 mils minimum at any point. |
| Shielding | (Optional) One or more may be shielded. |
| Jacket | PVC, Class 43, 20 mils minimum average, 16 mils minimum at any point. |
| Assembly | Cable may be either straight or wound in retractile form. Core may be either flat or round. Barrier layer and/or fillers optional. |
| Standard | Appliance Wiring Material UL 758 |
| Instructions to UL Representative | Detailed Examination. |
| UL Counter-Check Program | (4) Detailed Examination. |
| (4) Physical Properties of Insulation and Jacket, Unaged and Aged. | |
| (4) Heat Shock. | |
| (4) Cold Bend. | |
| (4) Deformation. | |
| (12) Horizontal Flame Test on Cable. | |
| Marking | General. |
| Use | Internal cable of electronic equipment, or as "Handset Wire or Telephone Cord for Subscriber Sets" |
Company Details
Focusing on a customer-centric approach, Pan-international Wire And Cable (M) Sdn. Bhd. has a pan-India presence and caters to a huge consumer base throughout the country. Buy Cables/Cable Accessories & Conductors in bulk from Pan-international Wire And Cable (M) Sdn. Bhd. at Trade India quality-assured products.
Business Type
Exporter, Manufacturer, Supplier
Employee Count
250
Establishment
1994
Working Days
Monday To Sunday
Related Products
Explore Related Categories
More Product From This seller
Seller Details
Penang, Pulau Pinang
Product And Business Development Manager
Mr. Edwin Cheow
Address
Plot 6, Jalan Jelawat Satu, Kawasan Perusahaan Seberang Jaya, Penang, Pulau Pinang, 13700, Malaysia
electronic cables in Penang
Report incorrect details






































