voice searchcamera search
Medical Pathological Microscopes - Monocular, 45â° Viewing Head, Quadruple Nosepiece, Achro Objectives 4x-100x, 120x120mm Mechanical Stage, Led Light Source | Moveable Abbe Condenser, Supplied With Manual & Dust Cover

Medical Pathological Microscopes - Monocular, 45â° Viewing Head, Quadruple Nosepiece, Achro Objectives 4x-100x, 120x120mm Mechanical Stage, Led Light Source | Moveable Abbe Condenser, Supplied With Manual & Dust Cover

Get Latest Price

Minimum Order Quantity :

1 Piece

Brand Name :

Edutek

In Stock

In Stock

Product Specifications

Viewing HeadMonocular
EyepieceWF 10x-18mm
NosepieceQuadruple
Objectives4x, 10x, 40x, 100x
Mechanical Stage120x120mm
CondenserAbbe N A 1.25
Light SourceLED
UsagePathological examination of tissue samples and other specimens.
FeaturesHigh resolution, Precise focusing, Durable design, Easy operation, Clear images, Wide field
Spare PartsAvailable (lamp, fuse, eyepieces, objectives, stage clips, etc.)
Focus SystemCoaxial coarse and fine focusing mechanism
View HeadBinocular/Trinocular, Interpupillary & Diopter Adjustment
TheoryOther, Optical Transmission and Reflection
DrawtubeTrinocular
SensorHigh Sensitivity CMOS (when attached with camera)
ResolutionUp to 1920 x 1080 pixels (digital imaging)
InterfaceUSB 2.0 (when camera attached)
Frame RateUp to 30fps (with digital camera)
Focal Distance160 mm (standard)
Magnification40X - 1500X (with different objectives and eyepieces)
Dimensions430 x 285 x 180 mm (approx)
Focus RangeUp to 15mm Coarse/0.002mm Fine
EyepiecesWide Field WF10X / WF16X (optional)
Eyepiece TubeInclined 45A,Adeg, rotatable 360A,Adeg
IlluminationLED or Halogen 6V/20W, transmitted and/or reflected
Coarse Adjustment Range30 mm
Fine Adjustment Range0.002 mm per division
Working StageMechanical Double Layer, 125 x 115 mm, with X-Y movement
Still Image Capture ResolutionUp to 5 MP (depends on camera)
Video Capture Resolution1080p Full HD (depends on camera)
Image FormatJPEG/PNG (with camera)
Interpupillary Distance55 - 75 mm adjustable
Objective Achromatic4X, 10X, 40X (SL), 100X (SL Oil)
Payment TermsCash Advance (CA), Cash in Advance (CID), Cheque, Telegraphic Transfer (T/T), Letter of Credit (L/C)
Sample AvailableYes
Sample PolicySample costs shipping and taxes has to be paid by the buyer
Packaging Detailscarton box, export quality also available
Main Export Market(s)Asia, Eastern Europe, Western Europe, Middle East, Africa
Main Domestic MarketAll India
CertificationsISO 9001, 14001 ,CE

Company Details

Manufacturer and Exporter of all type engineering lab equipment, civil engineering lab equipment, science lab equipment, soil testing lab equipment, concrete Testing Lab Equipment, Vocational Training Equipment, Teaching lab equipment, Pharmacy Lab Equipment, Mechanical Lab for engineering college, fluid mechanic lab for engineering students, etc

Business Type

Exporter, Manufacturer, Supplier

Employee Count

25

Establishment

1973

Working Days

Monday To Saturday

GST NO

06AEWPJ6896D1ZU

Certification

AN ISO 9001:2008

Related Products

Explore Related Categories

More Products From This Seller

Seller Details

GST

GST - 06AEWPJ6896D1ZU

Trusted SellerTrustedSeller

Ambala Cantt, Haryana

Director-International Sales

Mr Aditya Kumar

Members since

12 Years

Address

Factory: 70, Edutek House, Main Road Vikaspuri, Industrial Area, Ambala Cantt, Haryana, 133006, India

pathological microscope in Ambala Cantt

Report incorrect details

Compare With Similar Products

Buyer Feedback

3

4

4

Minimum Order Quantity

1 Piece/Pieces

1 Unit/Units

Features

Anti-fungal coated optics, Sturdy Metal Stand, Smooth Mechanical Movements

Anti-fungal optics, ergonomic design, sturdy metal frame, wide-field observation, suitable for research and education

Spare Parts

Available (lamp, fuse, eyepieces, objectives, stage clips, etc.)

Fuse, bulb, lens cleaning cloth, power cord

Focus System

Coaxial coarse and fine focusing mechanism

Coaxial coarse and fine focusing

View Head

Binocular/Trinocular, Interpupillary & Diopter Adjustment

Trinocular, sliding type

Theory

Other, Optical Transmission and Reflection

Other, Pathological research microscope designed for diverse clinical and laboratory applications.

Drawtube

Trinocular

Trinocular

Sensor

High Sensitivity CMOS (when attached with camera)

CMOS Sensor

Resolution

Up to 1920 x 1080 pixels (digital imaging)

1920 x 1080 pixels

Interface

USB 2.0 (when camera attached)

USB 2.0, HDMI

Frame Rate

Up to 30fps (with digital camera)

30fps at full resolution

Focal Distance

160 mm (standard)

45 mm

Magnification

40X - 1500X (with different objectives and eyepieces)

40X to 1000X

Dimensions

430 x 285 x 180 mm (approx)

400 x 235 x 420 mm

Focus Range

Up to 15mm Coarse/0.002mm Fine

8 mm

Eyepieces

Wide Field WF10X / WF16X (optional)

WF10x/20mm, high eye-point

Eyepiece Tube

Inclined 45A,Adeg, rotatable 360A,Adeg

Inclined 30Adeg, rotatable 360Adeg

Illumination

LED or Halogen 6V/20W, transmitted and/or reflected

LED, 3W with adjustable brightness

Coarse Adjustment Range

30 mm

30 mm

Fine Adjustment Range

0.002 mm per division

0.002 mm

Working Stage

Mechanical Double Layer, 125 x 115 mm, with X-Y movement

Double layer mechanical stage, 140 x 140 mm with 75 x 50 mm moving range

Still Image Capture Resolution

Up to 5 MP (depends on camera)

2 Megapixel

Video Capture Resolution

1080p Full HD (depends on camera)

Full HD 1080p

Image Format

JPEG/PNG (with camera)

JPG, BMP, TIFF

Interpupillary Distance

55 - 75 mm adjustable

55-75 mm adjustable

Objective Achromatic

4X, 10X, 40X (SL), 100X (SL Oil)

4x, 10x, 40x (S), 100x (S, Oil) DIN

Condenser

NA 1.25 Abbe Condenser with Iris Diaphragm and Filter Holder

Abbe condenser N.A. 1.25 with iris diaphragm and filter

Light Source

LED Illumination, intensity adjustable

Built-in LED, 100-240V AC

Main Domestic Market