voice search
Industrial Ups System - 3 Phase Power Protection, Flexible Adaptability For Small To Medium Data Centers And Facilities, High Reliability With Redundant Components
Share

Industrial Ups System - 3 Phase Power Protection, Flexible Adaptability For Small To Medium Data Centers And Facilities, High Reliability With Redundant Components

Price:

Get Latest Price

In Stock

In Stock

Product Specifications

UPS Rating (kVA/kW)20-120/16-96
Input Voltage250-470V
Output Voltage380-415V
Frequency50/60Hz
EfficiencyUp to 94%
Overload Capacity150%
UsageData centers, buildings, facilities
THD<2%
FeaturesHigh Availability, Power Protection, Scalable Power, Easy Monitoring, Fault Tolerance, Cost Effective, High Efficiency, Parallel Capable

Product Overview

Key Features


Industrial UPS System



Performance
3 Phase Power Protection with Adaptability to meet the unique
requirements of Small to Medium Data centers, Building and  Facilities.



  • Flexible and adaptable
  • Advance electrical features
  • Intuitive Monitoring
  • Parallel capable
  • High availability architectures component





High Power Availability












The MGE Galaxy 5000 has been designed
for continuous operation









  • Fault tolerance with built-in 100% rated bypass static switch
  • Redundant components for greater reliability
  • High overload capacity to improve downstream discrimination
  • Extended Battery backup times available











Flexible and Upgradeable












The MGE Galaxy 5000 adapts to your
changing needs












  • Expandable Power ranges
  • Parallel up to 6 modules for higher capacity or redundancy
  • Easy integration with networking and monitoring systems
  • A choice of backup times from 5 minutes to 8 hours
  • Compatible with inductive and leading power factor loads
  • Field Upgradeable from Single to Parallel


Low total cost of ownership









The MGE Galaxy 5000 helps to minimize
your infrastructure costs












  • Small footprint
  • Power factor corrected input prevents the need for oversizing cables, circuit breakers and generator
  • Efficiency in on-line double conversion mode up to 93.5%


Features that make difference






IGBT based technology for Power Quality









Supplies clean, stable power to
sensitive loads ensuring critical power protection, optimum
performance, and extended life.









Parallel Operation









Connect as many as 6 units in parallel
for capacity and redundancy to grow with your power requirements









Dual Input









Allows for connection to two separate
input sources for increased availability












Redundant Components









Back up for the Main Intelligence
Module provides increased availability












Built-In Static and maintenance Bypass









Enables the UPS to transfer the load to
utility power, without interruption, in the event of heavy overload
or fault












Optional Auxiliary Gear



  • Input/Output transformers-380V/400V/415V
  • Wall Mount Battery Disconnect
  • Matching Battery Cabinets-Up to four (4) enclosures can be connected to the UPS for extended run times of up to 4 hours
  • Distribution
    • Panel board
    • Sub Feed Breakers
  • Matching External Maintenance Bypass
  • Parallel System Bypass Cabinets
  • Communication cards
    • RS232 / RS485 / Dry Contact
    • Network Management Card
  • Bottom Entry Cabinets
  • 65kAIC rating
  • Remote Alarm Panel















Technical Specifications


























































































































































































































































































UPS Rating kVA/KW (PF = 0.8)



20/16



30/24



40/32



60/48



80/64



100/80



120/96



Normal AC supply input



Input voltage range (V)



250V to 470V 3-phase



Inputs mains 1 and Mains 2



Separate or Common



Frequency



50Hz/60Hz+-8%



Input power factor



>0.99



Input current total harmonic distortion (THDI)



<3%



Bypass system input



Nominal input voltage



340V to 470V 3-phase+ neutral



Frequency



50Hz/60Hz +8%



Output



Output voltages (V)



380V-400V-415V+3%, 3-Phase+neutral



Frequency (Hz)



50Hz/60Hz



Voltage Regulation



+1%



Overload



150% 1 minute, 125% 10 minutes



Output voltage total harmonic distortion



THDU <2%



Max load crest factor



3:1



Overall efficiency



Double conversion mode



Up to 94%



Economy mode



Up to 97%



Environmental



Storage temperature



25oC to +45oC



Operating temperature



Up to 40oC (2)



Operating altitude



1000m



Parallel connection



Modular



Up to 6 modules



Standards and approvals



Performance and safety



IEC/EN 62040-1, IEC/EN 60950



Performance and design



IEC/EN 62040-3



Design and manufacturing



ISO 14001, ISO 9001, IEC 60146



EMC immunity



IEC 61000-4-2 to 6



EMC emissions



IEC 62040-2 C3



Approvals



TUV-LCIE-CEM-CE Mark



Dimensions and weights (depth=850mm and
height=1900 mm)







20



30



40



60



80



100



120



UPS with out batteries (width in mm)



710



Weight



400 kg



520 kg



UPS+ built-in batteries (width in mm)



1010



From 5 minutes to 35 minutes (3)















738 kg



888 kg



1050kg







From 10 minutes to 50 minutes (3)



732 kg



888 kg























From 15 minutes to 90 minutes (3)



















975 kg











From 20 minutes to 110 minute (3)



738kg



888kg























From 30 minutes to 120 minutes (3)



888kg



975kg























Battery cubicles (width and weight)



From 5 minutes to 35 minutes (3) width in mm



710



From 5 minutes to 35 minutes (3) weight



885 kg



980kg



From 10 minutes to 50 minutes (3) width in mm



710



1010



From 10 minutes to 50 minutes (3) weight



885 kg



1142kg



1307kg



From 15 minutes to 80 minutes (3) width in mm



710



1010



1010



2x1010



From 15 minutes to 80 minutes (3) weight



885 kg



1142kg



1307kg



1764kg



From 30 minutes to 120 minutes (3) (width in mm)



710



1010



2x710



710+1010



2x1010



From 30 minutes to 120 minutes (3) weight



882kg



1307kg



1764kg



2439kg



2742kg


















Company Details

POWER SOLUTIONS, Established in 2008 at Chandigarh in Chandigarh, is a leading service provider of UPS & Power Supply in India. POWER SOLUTIONS is one of Trade India's verified and trusted names for listed services. With extensive experience in the field of UPS & Power Supply, POWER SOLUTIONS has made a reputed name for itself in the market with satisfactory Home Lighting Ups, Home Power Solutions, Home UPS, etc.
Focusing on a customer-centric approach, POWER SOLUTIONS has a pan-India presence and caters to a huge consumer base throughout the country. Get UPS & Power Supply from POWER SOLUTIONS at Trade India quality-assured services.

Business Type

Manufacturer, Service Provider, Supplier

Establishment

2008

GST NO

04AQSPK7636A1ZU

Related Products

Explore Related Categories

More Product From This seller

Seller Details

GST

GST - 04AQSPK7636A1ZU

5 RatingRating

Chandigarh, Chandigarh

Seller Inquiry

Accepts only Domestic inquiries

Proprietor

Mr. Ravinder Kumar Dhiman

Address

Shop No. 436, Near Bus Stand, Maloya, Near Sector-39, Chandigarh, Chandigarh, 160036, India

industrial ups system in Chandigarh

Report incorrect details

Compare With Similar Products

Buyer Feedback

5

3

Price Or Price Range

530 INR

800 INR

Minimum Order Quantity

50 Unit/Units

100 Kilograms/Kilograms

Color

Grey

Grey

Usage

Lighting Use

Industrial Use

Material

Aluminum

Product Type

Sudarshan LED Street Light 36W

Aluminium Gravity Die Castings

Delivery Time

5 Days

1 Week

Main Domestic Market

All India

All India

Packaging Details

Box

Box

Supply Ability

10 Per Day

1000 Per Week