Sensor TypeElectrochemical
MaterialABS Plastic
Dimensions70x50 mm
Operating Temp0-50°C
Power SupplyDC 24V
Sensitivity10ppm
Alarm OutputRelay
FeaturesEarly detection, Accurate sensing, Reliable alerts, Easy installation, Durable design, Low maintenance

Product Overview

Key Features

We have gained high acclamation from our clients due to the outstanding range of Gas Leak Sensor designed and offered by us. Further, these Gas Leak Sensor are made under the strict supervision of our expert and skilled manpower. Therefore these are free from every default and accomplishing all the prescribed industrial norms.

Company Details

KM Electronic Cables Pvt. Ltd., Established in 1991 at Ahmedabad in Gujarat, is a leading Importer,Manufacturer,Supplier,Trading Company of Sensors in India. KM Electronic Cables Pvt. Ltd. is one of Trade India's verified and trusted sellers of listed products. With extensive experience in supplying and trading Gas Leak Sensor, KM Electronic Cables Pvt. Ltd. has made a reputed name for itself in the market with high-quality Gas Leak Sensor, etc.
Focusing on a customer-centric approach, KM Electronic Cables Pvt. Ltd. has a pan-India presence and caters to a huge consumer base throughout the country. Buy Sensors in bulk from KM Electronic Cables Pvt. Ltd. at Trade India quality-assured products.

Business Type

Importer, Manufacturer, Supplier, Trading Company

Establishment

1991

Working Days

Monday To Sunday

Related Products

Explore Related Categories

More Products From This Seller

Seller Details

Ahmedabad, Gujarat

Technical Director

Mr. Daksham K. Ratanchandani

Address

K.M. House, Opp. Maurya Complex, Near C.U. Shah College, Income Tax Circle, Ashram Road, Ahmedabad, Gujarat, 380014, India

hydrogen sensor in Ahmedabad

Report incorrect details

Compare With Similar Products

Minimum Order Quantity

1 Set/Sets

1 Pack/Packs

Material

316 SS Stainless steel Cell block

Gas Sensor

Voltage

10 aEUR" 35 VDC Watt (w)

24v Ampere (amp)

Warranty

1 year

1 year

Payment Terms

Telegraphic Transfer (T/T)

Cash on Delivery (COD), Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)

Supply Ability

5000 Per Year

100 Per Day

Delivery Time

1 Months

1 Days

Sample Policy

Contact us for information regarding our sample policy

Within a certain price range free samples are available

Main Export Market(s)

Australia, North America, Eastern Europe, Middle East, Africa, Western Europe, South America, Asia, Central America

Australia, Asia

Main Domestic Market

All India

All India

Certifications

ISO9001

Battery rooms or battery charging bays or battery charging stacks are being widely used in Data Center, UPS Systems, Renewable Energy Sources like Solar Plants, Wind farms, Submarines, Naval Vessels and Underground Bunkers etc.Features:MA-2-3440-F-MMSR, Germany micro-gard Hydrogen sensor transmitter, Catalytic pellistor, 0-100% LEL H2 in IP44 enclosure with features:A* Continuous monitoringA* Low zero point driftA* Poisoning stableA* Long life sensorA* Easy maintenance / calibrationA* Reverse polarity protectedA* Overload protectedA* IP 44 protected enclosureA* Response time <10secA* Short circuit reverse polarity protectedA* Plug-in sensor PCB for easy service and replacementA* 24 VDC 4-20mA output or 2-10 VDC outputThese batteries when being charged generate, liberate highly explosive Hydrogen (H2) gas. The LEL(Lower Explosive Limit) of Hydrogen (H2) is 4 % Vol. and the UEL (Upper Explosive Limit) is 77 % Vol. Hydrogen (H2) is lighter than air and travels towards ceiling in an enclosed battery room.The potential risk of this Hydrogen (H2) generation liberation in battery rooms are:Potential of creating highly explosive atmosphere which can create explosions in the battery rooms due to electrical sparks, electrical short-circuits, electrical earth leakage and high surge capacitive discharge.Oxygen depletion atmosphere in an enclosed battery rooms there by causing breathing safety hazard for working humans.Solutions:To design engineer install a continuous Hydrogen (H2) detection and monitoring system and to control the ventilation fans to remove the built-up Hydrogen (H2) gas.ALVI Automation India in association with Gas Alarm Systems, Sydney Australia and MSR, Germany can design, engineer and supply Hydrogen (H2) sensor transmitter along with gas monitoring control panels for controlling the ventilation fans in the battery rooms to dissipate the explosive atmosphere. We have range of sensor transmitter with 4-20 mA analog output, stand alone single point gas controllers, multi channel digital Modbus centralised gas control systems.MSR, Germany product range includes ATEX, IEC-Ex, SIL2 Hazardous area certified for zone-1 and zone-2 hazardous atmospheres.All from MSR, Germany hence quality and reliability are assured. All systems supplied by ALVI Automation India will be supported, calibrated, maintained, serviced as per Global standards.

People Also Viewed