Digital Multimeter Fluke 15bmax - Accuracy: As Per Manual %
Price: 12744.00 INR / Number Number Unit
(10800.00 INR + 18% GST)
Get Latest Price
MRP:
12744.00 INR / Number
Weight :
455.00 Gram
1 Pack Contains :
1
Minimum Pack Size :
1
In Stock
Product Specifications
| Resolution | As per manual |
| Size | 183 mm x 91 mm x 49.5 mm |
| Usage | To measure electrical outputs like voltage, current, resistance etc. |
| Product Type | Measuring Instruments |
| Measurement Range | As per manual |
| Weight | 455 Grams (g) |
| Width | 91 Millimeter (mm) |
| Height | 183 Millimeter (mm) |
| Length | 49.5 Millimeter (mm) |
| Accuracy | As per manual % |
| Range | As per manual |
| Payment Terms | Paypal, Cash in Advance (CID), Cheque |
| Supply Ability | 35 Per Week |
| Delivery Time | 1 Week |
| Sample Available | No |
| Sample Policy | Contact us for information regarding our sample policy |
| Packaging Details | BOX |
| Main Export Market(s) | Asia, Australia, Middle East, Africa |
| Main Domestic Market | All India, South India, Central India, West India, North India, East India |
| Certifications | ISO 9001:2015 |
| MRP | 12744.00 INR |
| Mop | 1 |
| Price | 10800.00 INR (Approx.) |
| Moq | 1 |
| Pkg Box Breadth | 9.10 cm |
| Packsize | 1 |
| Unit Type | Number |
| Shipping Type | actual |
| Currency | INR |
| GSTIN | 18% |
| Pkg Box Height | 18.30 cm |
| Stock Quantity | 1 |
| Product Unit | 1 Number |
| Pkg Box Length | 4.95 cm |
| Weight | 455.00 Gram |
| Returnable | No |
| Brand Name | Fluke |
| Price Type | fixed |
| Minimum Ordered Packs | 1 |
| Minimum Order Quantity | 1 |
Product Overview
Key Features
Key features
* Audible and visual alarm for incorrect connections
* Test leads with fines tips for circuit board testing
* Simple interface to wake meter from sleep mode by activating any buttons
* Voltage: 6000-count reading
* Capacitance range: 2000uF
* Safety rating: CATIII 600V
Specifications: Fluke 15B MAX Economical Digital Multimeter
| Specifications | ||||
|---|---|---|---|---|
| Accuracy is specified for 1 year after calibration, at operating temperatures of 18 C to 28 C, relative humidity at 0 % to 75 % Accuracy specifications take the form of: ([% of Reading] + [Number of Least Significant Digits]). | ||||
| Function | Range | Resolution | Accuracy | |
| 15B MAX | 17B MAX | |||
| AC Volts (40 Hz to 500 Hz)1 | 6.000 V 60.00 V 600.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 1.0 % + 3 | 1.0 % + 3 |
| AC Millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 | 3.0 % + 3 |
| DC Volts | 6.000 V 60.00 V 600.0 V 1000 V | 0.001 V 0.01 V 0.1 V 1 V | 0.5 % + 3 | 0.5 % + 3 |
| DC Millivolts | 600.0 mV | 0.1 mV | 1.0 % + 10 | 1.0 % + 10 |
| AC Current A (40 Hz to 400 Hz)2 | 400.0 A 4000 A | 0.1 A 1 A | 1.5 % + 3 | 1.5 % + 3 |
| AC Current mA (40 Hz to 400 Hz)2 | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5 % + 3 | 1.5 % + 3 |
| AC Current A (40 Hz to 400 Hz)2 | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | 1.5 % + 3 |
| DC Current A2 | 400.0 A 4000 A | 0.1 A 1 A | 1.5 % + 3 | 1.5 % + 3 |
| DC Current mA2 | 40.00 mA 400.0 mA | 0.01 mA 0.1 mA | 1.5 % + 3 | 1.5 % + 3 |
| DC Current A2 | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | 1.5 % + 3 |
| Diode Test3 | 2.000 V | 0.001 V | 10% | 10% |
| Temperature 4 | 50.0 C to 400.0 C 0 C to 50.0 C -55.0 C to 0 C | 0.1 C | NA | 2 %+1 C 2 C 9 %+2 C |
| Resistance (Ohms)5 | 400.0 4.000 k 40.00 k 400.0 k 4.000 M 40.00 M | 0.1 0.001 k 0.01 k 0.1 k 0.001 M 0.01 M | 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 | 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
| Capacitance6 | 40.00 nF 400.0 nF 4.000 F 40.00 F 400.0 F 2000 F | 0.01 nF 0.1 nF 0.001 F 0.01 F 0.1 F 1 F | 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 | 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
| Frequency1(10 Hz to 100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | NA | 0.1 % + 3 |
| Duty Cycle1 | 1% to 99% | 0.10% | NA | 1 % typical7 |
| Continuity Threshold | 70 | 70 | ||
| Backlight | Yes | Yes | ||
| 1All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. 2Typical burden voltage: DC/AC Current A: 100 V / A; DC/AC Current mA: 2 mV/mA; DC/AC Current A: 0.03 V/A 3Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA 4Use Type K thermocouple 5Typical open circuit test voltage is 0.54 V, maximum short circuit current is 1.8 mA 6Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). 7Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %. | ||||
| Input Characteristics | ||||
|---|---|---|---|---|
| Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio | Normal Mode Rejection Ratio |
| AC Volts | 1000 V1 | >10 M, <100 pF | >60 dB at 50 Hz or 60 Hz | |
| AC Millivolts | 1000 V1 | >1 M, <100 pF | >80 dB at 50 Hz or 60 Hz | |
| DC Volts | 1000 V1 | >10 M, <100 pF | >100 dB at 50 Hz or 60 Hz | >60 dB at 50 Hz or 60 Hz |
| DC Millivolts | 1000 V1 | >1 M, <100 pF | >80 dB at 50 Hz or 60 Hz | |
| 1106V Hz max | ||||
| General Specifications | |
| Maximum voltage between any Terminal and Earth Ground | 600 V |
| Maximum differential voltage between V and COM terminals | 1000V |
| Display (LCD) | 6000 counts, updates 3/sec |
| Battery Type | 2 AA, IEC LR6 |
| Battery life | 500 hours minimum |
| Temperature | Operating 0 C to 40 C; Storage -30 C to 60 C |
| Relative Humidity | Operating Humidity Non-condensing (<10 C); 90 % RH at 10 C to 30 C; 75 % RH at 30 C to 40 C |
| Operating Humidity, 40 M range | 80 % RH at 10 C to 30 C; 70 % RH at 30 C to 40 C |
| Altitude | Operating 2000 m; Storage 12000 m |
| Temperature Coefficient | 0.1 X (specified accuracy) /C (<18 C or >28 C) |
| Fuse protection for current inputs | 440 mA, 1000 V, fast-blow, use only Fluke specified parts. 11 A, 1000 V, fast-blow, use only Fluke specified parts |
| Size (HxWxL) | 183 mm x 91 mm x 49.5 mm |
| Weight | 455 g |
| Ingress Protection | IP40 |
| Safety | IEC 61010-1, IEC61010-2-030: CAT III 600 V, Pollution Degree 2 |
| Electromagnetic Environment | IEC 61326-1: Portable |
| Electromagnetic Compatibility (EMC) | Only applicable in Korea |
Company Details
At Trygen Instruments, we are committed to delivering excellence in the sales and services of precision equipment and instruments for calibration, testing laboratories, the pharmaceutical industry, and the automotive sector.
Trygen Instruments stands out as a leading sales and service company known for its commitment to quality, reliability, and customer satisfaction. Specializing in precision instruments and advanced technological solutions, Trygen consistently delivers high-performance products tailored to meet the unique needs of various industries.
What truly sets Trygen apart is its exceptional after-sales service, with a dedicated support team that ensures smooth operation and long-term value for every client. By combining technical expertise with a customer-centric approach, Trygen Instruments fosters lasting relationships and positions itself as a trusted partner in innovation and operational excellence.
Business Type
Exporter, Manufacturer, Service Provider, Distributor, Trading Company
Employee Count
5
Establishment
2025
Working Days
Monday To Saturday
GST NO
33AAYFT1263G1ZX
Related Products
Explore Related Categories
More Product From This seller
Seller Details
GST - 33AAYFT1263G1ZX
Krishnagiri, Tamil Nadu
Managing Director
Mr Prabaharan Thennavan
Address
7/500/1, Raja City, Thotagiri, Avalapalli, Krishnagiri, Tamil Nadu, 635109, India
Report incorrect details