| Accuracy | 0.5% +2 digit |
| Channels | 32 |
| Data Storage | 1,000,000 cycles |
| Display | Four-line LCD |
| Features | User-friendly, Automatic cycle, PLC comms, Data storage, Ethernet port |
| Leak Range | -5000 to +5000 Pa |
| Measuring Principle | Pressure decay |
| Pressure Range | 0.1-10 bar |
| Resolution | 1 Pa |
| Usage | Leak detection in various industrial applications, ensuring product quality and safety. |
Product Overview
Key Features
The Instrument is based on the principle of Differential Pressure Decay between two parts, a test part and a reference part with Automatic Measuring Cycle for manual and Automatic test Benches for Dry Air to Air Leak Testing.
Technical Specifications :
Leak Measurement by Differential Pressure Decay.
Pressure Range : 0.1-10 bar
Unit Adjustable (Bar, Kpa, MPa, PSI)
Leak range -500 to +500Pa
-1000 to +1000Pa
-5000 to +5000Pa
Maximum Resolution 1 Pa
Linearity <0.5% of full Scale
Accuracy 0.5% of Measured Value +2digit.
Main Features :
* User Friendly.
* Automatic Measuring Cycle.
* 4 Inputs and 4 Outputs for PLC Communications.
* 32 Noi? s of different Channels for different test cycles.
* Parameters are easily Programmable with the help of Monitor, Mouse, & Keyboard..
* Adjustable Test Pressure and Reject Level.
* Four Line LCD Display for Pressure, Leak Value and Test Results.
* Data Storage of test results for more than ten lac (1,000,000) cycles with the value of Test Pressure, Leak rate, both the Units, Test Results, Program No., Production count date & time of Testing.
Ethernet Port to retrieve data.
Company Details
CORONA PROCESS CONTROL is listed in Trade India's list of verified sellers offering supreme quality of Cylinder Head Cover Leak Testing Machine, Differential Pressure Decay Leak Tester, Differential Pressure Decay Leak Testing Machine, etc. Buy Leak Testing Equipment in bulk from us for the best quality products and service.
Business Type
Manufacturer, Supplier, Trading Company
Employee Count
4
Establishment
2007
Related Products
Explore Related Categories
More Products From This Seller
Seller Details
Delhi, Delhi
Accepts only Domestic inquiries
Proprietor
Mr. Puneet Gupta
Address
599, Gali No. 5, Shalimar Park Extension, Shahdara, Delhi, Delhi, 110032, India
leak testing machine in Delhi
Report incorrect details