Product Specifications
| Input voltage | 230V/380V |
| Input frequency | 50Hz |
| Output voltage | 220V/380V |
| Output frequency | 50Hz |
| Waveform | True sine wave |
| Efficiency | 95% |
| Power factor | 0.8 |
| Features | True online UPS, Dual conversion, High efficiency, Scalable runtime, Easy monitoring, Parallel operation, Generator compatible, Advanced battery management |
Product Overview
Key Features
- Three phases in, three phases out
- True on-line dual conversion design
- SPWM
- IGBT inverter design
- UPS can carry 100% non - balance load
- Extendable run time
- On-line, battery status/Led/LCD display (Touch Screen)
- Advanced Paralleling Option
- Generator compatible
- Cold start
- Load/battery capacity display
- Overload
- Advanced Battery management
- RS-232
- Optional SNMP card
Features of Version 3.0
Microprocessor Based Design
"Brain Built in" - UPS System function with the help of factory fed bios in the Microprocessor. There is no better way for the mankind to achieve 100% accuracy. Pure computer graded 220 Volts & 50Hz frequency is assured always.
Galvanic Isolation Technique
An International Technique of Isolating the input power from the input power source. This is the first stage of stabilization process for the wild power. The UPS system owns & operates on it's own pulses from this point to create a smooth inflow of power to the inverter and converter sections.
High Switching Frequency
UPS system is very quick in reacting to any input violence. sizeable deduction in size.
DB9 Connectivity for BMS applications & SNMP or RS 232 communication interface for PC/Servers
The power management information system (P-MIS), software to monitor the UPS system through an SNMP protocol, compatible to all popular operating system.
Toshibahybrid Ics
Symbol of safety - 100% out put short circuit protection
Inverter section
"EDD technology" (Electronic Digital Devices) for the first time in India.
Technical Specification
| Model | 1 Ph to 1 Ph | 3 Ph to 1 Ph | 3 Ph to 3 Ph | ||||||||||||||||||||
| 1000 | 2000 | 3000 | 4000 | 7500 | 1000 | 15000 | 20000 | 30000 | 10000 | 150000 | 20000 | 30000 | 400000 | 60000 | 600000 | 100000 | 120000 | 140000 | 160000 | 20000 | 25000 | 30000 | |
| Capacity | 1 | 2 | 3 | 6 | 7.5 | 10 | 15 | 20 | 30 | 10 | 15 | 20 | 30 | 40 | 60 | 80 | 100 | 120 | 140 | 160 | 200 | 250 | 300 |
| Operating Mode and Principle | |||||||||||||||||||||||
| True Orline, Static by Pass (uninterrupted Switch) Dual Conversion, Output Galvanic Isolation | |||||||||||||||||||||||
| AC Input | |||||||||||||||||||||||
| Phase | 1 Phase + N + G | 3 Phase + N + G | |||||||||||||||||||||
| Voltage | 230 + 25% | 380V + 25% | |||||||||||||||||||||
| Frequency | 50 Hz + 5% | 50 Hz + 5% | |||||||||||||||||||||
| P.F. | Unity | Unity | |||||||||||||||||||||
| Sort Start | 0-10% 5 S | 0-100 % 5 8 | |||||||||||||||||||||
| Bypass Input | |||||||||||||||||||||||
| Phase | Single Phase | 3 Phase + N + G | |||||||||||||||||||||
| Voltage | 220 V + 20% | 380 V + 25% | |||||||||||||||||||||
| Frequency | 50 Hz + 5% | 50 Hz + 5% | |||||||||||||||||||||
| Transfer Time | 0Ms, Inverter to bypass | 0 ms, Inverter to by pass (Overload) | |||||||||||||||||||||
| DC System | |||||||||||||||||||||||
| Voltage | 96/180/240 | 360/ 384/ 480 | |||||||||||||||||||||
| Charging Current | 1A to 50A (adjustable, Charge Current) | ||||||||||||||||||||||
| AC Output | |||||||||||||||||||||||
| Phase | Single Phase | 3 Phase + N + G | |||||||||||||||||||||
| Voltage | 220 + 1% (Stable Load); 220 + 1% (Fluctuated Load) | 380 + 1% (Stable Load); 380 + 5% (Floctuated Load) | |||||||||||||||||||||
| Frequency | 50 + 0.06% | 50 + 0.05% | |||||||||||||||||||||
| Power Factor | 0.8 | 0.8 | |||||||||||||||||||||
| Wave Form | True Sine Wave | True Sine Wave | |||||||||||||||||||||
| Harmonic Distortion | <3% (Linear Load) <5% (Non-Linear Load) | <3% (Linear Load) <5% (Non-Linear Load) | |||||||||||||||||||||
| Dynamic | Instantaneously charging of load ( 0 to 100%) Charging of out Voltage <5% | Instantaneously charging of load ( 0 to 100%) Charging of out Voltage <5% | |||||||||||||||||||||
| Transient Time | Transient Recovery Time <10ms | Transient Recovery Time <10ms | |||||||||||||||||||||
| Overload | 125% for 25min, 150% for 1 min. 200% for 30 sec. | 125% for 25min, 150% for 1 min 200% for 30 sec | |||||||||||||||||||||
| Cooling | Force Wind | Force Wind | |||||||||||||||||||||
| System | |||||||||||||||||||||||
| Efficiency | 93% & Above | ||||||||||||||||||||||
| Interface | RS 232, SNMP (Optional) | ||||||||||||||||||||||
| Temperature | 0-40% (Operating) | ||||||||||||||||||||||
| Humidity | 30-90% | ||||||||||||||||||||||
| Noise (dB) | 45-60 | 53-65 | 55-65 | 53-65 | 55-85 | 58-65 | |||||||||||||||||
Company Details
Focusing on a customer-centric approach, THE POWER ELECTRONICS has a pan-India presence and caters to a huge consumer base throughout the country. Get Inverters & Ups Equipment from THE POWER ELECTRONICS at Trade India quality-assured services.
Business Type
Manufacturer, Service Provider, Supplier
Employee Count
4
GST NO
19ANCPM8916A1Z2
Related Products
Explore Related Categories
More Products From This Seller
Seller Details
GST - 19ANCPM8916A1Z2
Kolkata, West Bengal
Accepts only Domestic inquiries
Proprietor
Mr. Ramesh Mohanty
Address
No. 107 B, Gholarghat Road, Ashashanti Apartments, Ground Floor, Kolkata, West Bengal, 700060, India
industrial frequency inverter in Kolkata
Report incorrect details