Features & Optional inside Delta ConnectionCONTD..ON PAGE 02November 25, 2016REF NO: DAPL/QTN/1159/16-17PRODUCT OFFERED We propose to offer Danfoss Make VLT FC 302 series AC Drive as per your requirement.BUILT-IN FEATURES OF DRIVE High Ambient - Rated for 50 Deg C Ambient operations; best suitable for harsh environment Built-in line chokes (two limbs) reduces harmonic distortion to a acceptable limits NO NEED FOR EXTERNAL LINECHOKES. DISPLAY (detachable type) Back-lit Graphic LCD type, with Programming keys & on-board Manual Built-in PID Controller for optimum Close Loop Control EXTERNAL CONTROLLER NOT REQUIRED IN CASE OFCLOSE LOOP OPERATION. DRIVE CAN ACCEPT TWO CHANNEL ENCODER I/P of 24VDC Long motor cables up to 150 mtrs. Unscreened cable can be used Built-in Smart Logic Controller (UP TO 20 LOGICS & 8 TIMERS) 3C3 coating for Harsh Environment. INPUT / OUTPUT:Digital input (0 - 24V DC) 5 nos.Analogue Inputs (0 10V DC & 0/4 20 MA) 2 nos.Analogue Outputs (0/4 20 mA) 1 nos.Relay Outputs 1 no. (Potential free NO/NC/C): Capacity 240VAC, 2 AmpPRICE SCHEDULE - Danfoss make Frequency Converter in modular form (IP 20- Enclosure Protection). INPUT SUPPLY : 3Phase, 380500 VAC, 50 /60 Hz.DRIVE RATING ENQUIREDDRIVE MODELOFFEREDQTYCode No. 300_SER 131B0649FC-302PK75T5E20H2XGXXXXSXXXXA0BXCXXXXDXVLT AutomationDrive FC- 3020.75 KW / 1.0 HP, 380 - 500 VAC, IP20 / Chassis,RFI Class A2 (C3), No brake chopperDanfoss make VLTAutomationSeries (FC 302) A.CDrive.Code No. 300_SER 131X5922FC-302PK75T5E20H2XGXXXXSXXXXALBXCXXXXDXVLT AutomationDrive FC- 3020.75 KW / 1.0 HP, 380 - 500 VAC, IP20 / Chassis,RFI Class A2 (C3), No brake chopperDanfoss make VLTAutomationSeries (FC 302) A.CDrive.TERMS & CONDITION OF SUPPLY:PRICES : Prices Are Ex-works Ahmedabad.OTHER LEVIES : ED Extra @ 12.50 % Extra+ 5 % VAT + Packing & Freight at actual; if applicable to your AccountPAYMENT : 30 % Advance, Balance Against Performa Prior to Delivery.DELIVERY : 3 - 4 weeks from the date of receipt of commercially clear written Order.WARRANTY : 12 months from the date of Installation OR 13 months from the date of Invoice; whichever is earlier Subject to product malfunctioning OR problem due to any manufacturing defect.INSTALLATION: Installation charges will be according to policy, Allowance per man day per person and Actual To & Fro Conveyance tothe site+ Decent Lodging-Boarding at site for Service Engineer visit shall be borne by you.VALIDITY : 30 days from hereof. (Govt. force majeure conditions apply at time of delivery)