| Products/Services in category 'Electrical Goods, Equipment & Supplies'
|
 |
Neutral Earthing Resistor
Neutral Grounding Resistor(NGR): NGR is employed in AC distribution networks to limit the fault current which would flow from the transformer or generator neutral star point in the event of an earth fault in the systems. It is used when the neutral of supply transformer is accessible and its own impedance is not enough to limit fault current. The rating of the protection relays within the required time. For Grounding Neutral of Transformer or Generator, Resistors upto 33 KV are offered for fault of short duration like 10 sec., 30 sec., 60 sec., continuous etc. Material of resistor is no
...More |
|
 |
Neutral Grounding Resistor & Neutral Isolator Panels
PURPOSE Neutral Grounding / Earthing Resistors are employed in AC Distribution Networks to limit the Restricted Earth Current to a safe value which would flow from the Transformer or Generator star point in the event of an earth fault in the system without exceeding specified temperature limits. In case of short time rating, dissipation is negligible & the temperature rise for the resistor element depends on its capacity to store the energy generated in proportion to the mass & specific heat of the material used. Theses NGR,S are connected between the neutral point of transformer
...More |
|
 |
Load Bank
Our compactly designed range of load bank is a device used for developing electrical load and applying the same to an electrical power source to convert or dissolve the power output resulting from it. The load provided by the load bank can be effectively controlled with the aid of control devices, resulting in suitable functioning. Following are its application area: UPS system testing Testing the functioning of turbines Battery system testing Load optimization in heavy duty power applications
...More |
|
 |
Isolators / Load Break Switch
Isolators: We design and manufacture HT indoor isolators of the following rating: A) 3.3 KV./6.6 KV./12 KV./22 KV./33 KV. B) 400Amp./630 Amp./1200Amp./1800Amp./3200 Amp. Salient Features Single Pole / Three Pole ON Load/OFF Load Motorised/Manual mode of operation Availability of link drive/Aux. switch for switchboard operation/electrical indications and interlock purpose respectively. Can be mounted on walls, structures or in switchboards/panels. High operating reliability. Simple maintenance and inspection. Used mechanically strong fiberglass link
...More |
|
 |
Neutral Earthing Resistors Manufacturer
PURPOSE Neutral Grounding / Earthing Resistors are employed in AC Distribution Networks to limit the Restricted Earth Current to a safe value which would flow from the Transformer or Generator star point in the event of an earth fault in the system without exceeding specified temperature limits. In case of short time rating, dissipation is negligible & the temperature rise for the resistor element depends on its capacity to store the energy generated in proportion to the mass & specific heat of the material used. Theses NGR’S are connected between the neutral point of transformer
...More |
|
 |
Motorised Isolator Panels(NIS) with CT & PT.
Motorised Isolator Panels(NIS) with CT & PT: We design and develop an array of neutral isolator panels (NIS) with CT & PT that are highly reliable and yield better operational level. These products require less maintenance and are used operational Used mechanically strong fiberglass link instead of epoxy link to avoid regular problem. These panels can easily be mounted on the walls or any kind of switchboards and are available in single pole or three pole type. Our neutral isolator panels (NIS) with CT relay come with the following ratings: 3.3 KV./6.6 KV./12 KV./22 KV./33
...More |
|
 |
Neutral Isolator panels ( NIS)
DYNAMIC BREAKING RESISTOR In electric braking, traction motor acts as a generator. Kinetic Energy of a moving train converted into electrical energy is, dissipated in the form of heat. This is called ‘Dynamic Braking. Construction: Dynamic Braking Resistors are manufactured as per Customers requirement. Testing: All Routine Tests are conducted in-house. Following special tests are also conducted if required, Vibration Test Rain Test Hygroscopic Test. ISOLATORS HT indoor isolators of following rating 3.3 KV / 6.6 KV/ 12 KV / 22 KV / 33 KV.
...More |
|
 |
Neutral Grounding Resistor
Neutral Grounding Resistor(NGR): NGR is employed in AC distribution networks to limit the fault current which would flow from the transformer or generator neutral star point in the event of an earth fault in the systems. It is used when the neutral of supply transformer is accessible and its own impedance is not enough to limit fault current. The rating of the protection relays within the required time. For Grounding Neutral of Transformer or Generator, Resistors upto 33 KV are offered for fault of short duration like 10 sec., 30 sec., 60 sec., continuous etc. Material of resistor is no
...More |
|
 |
Starting/Speed Control Resistor
...More |
|
 |
Wire Wound, Wire Grid Resistance for NGR.
Wire Wound, Wire Grid Resistance Resistance wire is would on ceramic insulator to form a coil for wire wound. Tapping can be taken at any place. These Resistors are economical for low current. Available in ratings of 1 Amp and above. Neutral Grounding Resistors PURPOSE Neutral Grounding / Earthing Resistors are employed in AC Distribution Networks to limit the Restricted Earth Current to a safe value which would flow from the Transformer or Generator star point in the event of an earth fault in the system without exceeding specified temperature limits. In case of short time ratin
...More |
|
 |
Punched Stainless Steel Grids for NGR.
Punched Stainless Steel Grids: Grids are punched out of AISI 304/AISI 430 type stainless steel sheets or AISI-406 i.e. FeCrAl Sheets. Temperature coefficient of resistance is 0.094% per degree C for stainless steel AISI-304 & 0.15% per o C for AISI - 430 & 0.019% per o C for FeCrAl i.e. AISI-406. Connection between the adjacent grids can be following type: Adjacent grids will be connected by using galvanized Nut-Bolts using spring washers. With Tig welded joints, which are totally secured against intense vibration. Terminals can b
...More |
|
 |
Battery Discharge Resistors
...More |
|
 |
Formed Stainless Steel Grid
Wire-Resistance & Heating STARTING / SPEED CONTROL / BUFFER RESISTOR FOR MOTORS: For starting / Speed Control of A.C or D.C. Motors, resistors are manufactured as per customer's requirement at specified starting torque or for limiting initial inrush current to an acceptable value. Mainly these are used for cranes. Rating can be 2 minute, 5 minute, 10 minute, continuous or intermittent. Material of resistor is normally Stainless steel AISI-304, AISI -410 or AISI 430 or FeCrAl-AISI-406. QUALITY Standards Followed IPSS-1-10-002-82 with amendment no.1 and BS 587 for starting
...More |
|
|
Featured Products posted by this company in category 'Electrical Goods, Equipment & Supplies'
|
|
Neutral Side Cubicles
Our range of neutral side cubicles is widely useful in electrical power generating equipment, wherein there is an increasing need for measurement and limiting the current or the voltage. These are available in different configurations and specifications as per the purpose of application.
...More |
|
|
|
|
|
|
|
NATIONAL RESISTORS
SHOP NO.- 26, JIJAMATA MARKET, G-BLOCK, MIDC, SHAHU NAGAR, CHINCHWAD,
Pune - 411019, Maharashtra, India
Phone:91-20-27492231/64102003
Fax:91-20-27492231
Key Personnel
Mr. Vijay Patil
(Partner)
Mobile:+919225601280
Mr. Vishwanath Jetither
(Partner)
Mobile:+919226574323
Mrs. S. V. Patil
(Designer)
Mobile:+919226740802
|
| Last updated on : 18th July 2009 |