Indoor Power Solution
INDOOR POWER SYSTEM Delta Indoor power systems are equipped with a compact modular design with intelligent power features and state-of-the- art technology. The outstanding power density of the power system offers the best solution for space critical applications. The advanced technology as well as the extended temperature range, wide input voltage range and user friendly features are the key factors of the success with a cost effective and reliable solution. The systems are featured with Alarm Unit to provide alarms comprehensive remote monitoring Control.
...More |
|
 |
Outdoor Power Solution (IP 43-56)
Telecom Outdoor Solution from IP 43 to IP 56 Delta Outdoor Power System is especially designed to supply the power to the telecom outdoor equipments. The stable design is made for different environmental conditions, which provides the robustness for outdoor applications as well as the important protection against sun exposure and corrosion. The system is design as per the customer needs. Our basic design accommodates power system, AC-DC distribution unit, 19” mountable Telecom equipments i.e. Microwave. The complete outdoor system is equipped with all necessary and sophi
...More |
|
 |
TEC Approved Power System
TEC COMPLIANT POWER SYSTEM 25 A rectifier based power system is 100% compliant with TEC-GR no. GR/SMP-01/05.JANÂ’2005 including BHM(Battery Health Monitoring) 50A rectifier based power system is 100% compliant with TEC-GR no. GR/SMP-01/05.JANÂ’2005 including BHM(Battery Health Monitoring) 100A rectifier based power system is 100% compliant with TEC-GR no. GR/SMP-01/05.JANÂ’2005 including BHM(Battery Health Monitoring)
...More |
|
 |
E Series (1-3 kVA)
E Series (1-3 kVA) Technical Specifications : Power Ratings : 1 kVA / 700W 2 kVA / 1400W 3 kVA / 2100W Architecture : True On-Line Double Conversion Form Factor : Slim Tower Model Nominal Voltage : 230V AC Single Phase Input Voltage Range : 80 ~ 280 V * Input Frequency : 50 / 60 Hz ± 5 Hz (Auto Sensing) Input Power Factor : ≥ 0.97 Output Wave Form : Pure Sine Wave Typical Backup Time : Up to 4 Hours as Standard. Extended Backups can also be Provide
...More |
|
 |
N Series (1-3 kVA)
N Series (1-3 kVA) Technical Specifications : Power Ratings : 1 kVA / 700W 2 kVA / 1400W 3 kVA / 2100W Architecture : True On-Line Double Conversion Form Factor : Slim Tower Model Nominal Voltage : 220V / 230V / 240V (Selectable) Input Voltage Range : 80 ~ 280 V * Input Frequency : 50 / 60 Hz ± 5 Hz (Auto sensing) Input Power Factor : ≥ 0.97 Output Wave Form : Pure Sine Wave Typical Backup Time : Up to 4 Hours as Standard. Extended Backups
...More |
|
 |
R Series (1-3kVA)
R Series (1-3kVA) Technical Specifications : Power Ratings : 1 kVA / 700W 2 kVA / 1400W 3 kVA / 2100W Architecture : True On-Line Double Conversion Form Factor : Rack Mount / Tower Model Nominal Voltage : 220V / 230V / 240V (Selectable) Input Voltage Range : 80 ~ 280 V * Input Frequency : 50 / 60 Hz ± 5 Hz (Auto sensing) Input Power Factor : ≥ 0.97 Output Wave Form : Pure Sine Wave Typical Backup Time : Up to 4 Hours as standard. Extended Backups can also b
...More |
|
 |
R Series (5 - 11 kVA)
R Series (5 - 11 kVA) Technical Specifications : Power Ratings : 5 kVA / 3.5 kW 7 kVA / 4.9 kW 11 kVA / 8.0 kW Architecture : True On-Line Double Conversion Form Factor : Rack Mount / Tower Model Nominal Voltage: 200V / 208V / 220V / 230 V / 240 (Selectable) Input Voltage Range : 100 ~ 300 V * Input Frequency : 50 / 60 Hz ± 5 Hz (Auto sensing) Input Power Factor : > 0.99 Output Wave Form : Pure Sine Wave Typical Backup Time : Up to 4 Hours as standard. Extend
...More |
|
 |
J Series (5 - 11 kVA)
J Series (5 - 11 kVA) Technical Specifications : Power Ratings : 5 kVA / 4.0 kW 7 kVA / 4.9 kW 11 kVA / 8.0 kW 11 kVA / 7.7 kW (3:1) Architecture : True On-Line Double Conversion Form Factor : Rack Mount / Tower Model Nominal Voltage : 5 / 7 / 11 kVA : 200 / 208 / 220 / 230 / 240 V, 1-Phase 11 kVA (3:1) : 380 / 400 / 415 V, 3-Phase Input Voltage Range : 5 / 7 / 11 kVA : 120 ~ 280 V * 11 kVA (3:1) : 208 ~ 464 V ** Input Frequency : 50 / 60 Hz ± 0.5 ~ 5 Hz (Programmable
...More |
|
 |
H Series (15-30 kVA)
H Series (15-30 kVA) Technical Specifications : Power Ratings : 15 kVA / 12 kW (3:1 & 3:3) 20 kVA / 16 kW (3:1 & 3:3) 30 kVA / 24 kW (3:3) Architecture : True On-Line Double Conversion Form Factor : Floor standing Tower Model Nominal Voltage : 220 / 380, 230 / 400, 240 / 415 V (3-Phase 4-wire + ground) Input Voltage Range : 156 ~ 280 V (Phase to Neutral) / 270 ~ 485 V (Phase to Phase) Input Frequency : 50 / 60 Hz ± 3 Hz Input Power Factor : > 0.95 Output Voltage :
...More |
|
 |
NH Series (20-160 kVA)
NH Series (20-160 kVA) Technical Specifications : Power Ratings : 20 kVA / 16 kW 40 kVA / 32 kW 60 kVA / 48 kW 80 kVA / 64 kW Architecture : True On-Line Double Conversion Moudular UPS Form Factor : Floor standing Modular UPS Nominal Voltage : 220 / 380, 230 / 400, 240 / 415 V (3-Phase 4-wire + ground) Input Voltage Range : Nominal voltage -25% + 20% Input Frequency : 50 / 60 Hz (Range 45 ~ 65 Hz) Input Power Factor : > 0.99 Output Voltage : 220 / 380, 230 / 400, 240 / 41
...More |
|
 |
NT Series (20 -4000 kVA)
NT Series (20 -4000 kVA) Technical Specifications : Power Ratings : 20 / 30 / 40 / 50 / 60 / 180 kVA (3:1)* 20 / 30 / 40 / 50 / 60 / 80 / 100 / 120 / 160 / 200 / 260 / 320 / 400 / 500 kVA (3:3) as single module Capacity upto 4000 kVA available through paralleling of 8 modules Architecture : True On-Line Double Conversion Form Factor : Floor Standing Compact Model Nominal Voltage : 220 / 380, 230 / 400, 240 / 415 V (3-Phase 4-wire + ground) Input Voltage Range : Nominal Voltage ±20% Input Frequency : 50 / 60 Hz ±
...More |
|
 |
UPS Range From 1 kVA To 4000 kVA
Uninterrupted Power Supply In today′ s dynamic economic environment, corporate companies are doing everything to be ahead of their competition. Most of these companies employ state-of-the-art based latest equipments and hi-end technology based processes. Additionally, business flexibility and lower Total Cost of Ownership (TCO) along with faster Return on Investment (ROI) is equally important to keep an organization sustainable and growing at the same time. Surges, spikes, sags and blackouts happen daily but reliable electric power is the one thing corporate need to depend on, to give
...More |
|
 |
Power Supplies
...More |
|