Power Energy Conservation (I) Pvt. Ltd. is a manufacturer and exporter of Energy Meter, VIF Meter, RTU, Temperature, Lux/Light Meter, Sky Light, etc. We aim to reduce energy consumption by increasing the efficiency, redesigning, replacing, controlling and using the system effectively. An in-house quality assurance laboratory ensures that the quality standards are in conformance to international benchmarks, at every stage of the production. We have escalated to this level of success by producing and supplying high quality products, an exceptional level of service, better after sales support and transparency in ...More
Company Profile
Energy meter, vif meter, rtu, temperature meter, light meter, lux meter, sky light, electronic energy meter, rtu meter, energy conservation solutions, timer based push button switch, digital timers, temperature, lux/ light meter, energy conversion solution, consultancy & audits, digi ...
Business Type
:
Exporter / Service Provider / Manufacturer
Year Established
:
2006
Website
:
http://www.powerenergyconservation.com
Products Manufacturing and Exporting
:
Rtu, digital relay, energy meter, timer switch, lux meters, energy management system, measurement & meter, apfc, capacitor panel, electronic energy meter, static energy meters, kwh static energy meters, vif meter, light meter, energy conservation solutions, timer based push button switch, digital ti...
Services
:
Electrical consultancy, energy audit
Products/Services in category 'Power & Energy Measurement Equipments'
Regional Marketing Manager ( Maharashtra ) : Experience : 3 to 10 yrs Qualification Required: BE / B Tech / Diploma in electronics / Power electronics or electrical Responsibility : Yearly target setting , Business development of energy conservation solutions, Looking after dealer network , Expanding the dealer network throughout Maharashtra , Sales promotion activities, Launching new product, Concept selling, Collections etc Note : Freshers ma
PEC offers Consultancy for: Electrical System Design AND Audit Services for Audit for electrical system Audit for Electrical Safety Audit for energy usage. System Audit covers the adequacy of specification of equipments, cables etc vs the actual requirement keeping in consideration the future plans. The recommendation will be Indian Standards and best industry practices. Safety Audit covers The safety of electrical system equipments and cables etc. and reliability of distribution system.
Power Meter-Logger is a meter that is capable of not only measuring and displaying thirty-six electrical parameters but has the capability to log and store 1000 sets of five important parameters in internal memory. Facility to increase data logging facility for more than 1000 records is available on request. The recording interval is normally one hour but can be changed upon prior request. Any variation in load by more than 20 per cent is also recorded. The meter is provided with communication port and appropriate software for accessing recorded data. CT/PT ratio is programmable. Facility
Digital Time delay switch There are three type of Digital time delay switches available with us. However we can meet any custom specification. a. Model TDS1 : Time dealy range-selected at the client end using laptop or PC. Default Max. time set at factory end = 64 minutes. 8 pin dipswitch is provided. pin 1 to 4 are used for time selection.eg 0000 means 4 minutes, if max time is set at 64 minutes.0001 means 8 minues, for Max time = 64 min. The complete table for dipswitch is provided on the box. pin 7 of Dip switch is used for enabling / disabling retrigger
Typical Application : Used to switch off lights / device after set time from switch- on . It is used for toilets / bathrooms / or any area in industry or home which is less frequented and people have a tendency to forget to switch off. Specification : upto 500W , 230 V , 50 Hz , Single phase. Nob for setting 0- 30 minutes dalay for switching off the device/ light. Working Principle : Once the push button is pressed, it switches on the device/ lights. User can set a time dalay for switching off. Before it switches off the device , if user presses the button once again,
Power Meter-Logger is a meter that is capable of not only measuring and displaying thirty-six electrical parameters but has the capability to log and store 1000 sets of five important parameters in internal memory. Facility to increase data logging facility for more than 1000 records is available on request. The recording interval is normally one hour but can be changed upon prior request. Any variation in load by more than 20 per cent is also recorded. The meter is provided with communication p
...More
Application : To Interface with devices
Specification :
8 numbers optically isolated Relay output (may be expanded up-to 16 optionally),
Relay output 230V , 10 A or 400V , 5 Amp. User may specify
20X4 alphanumeric backlit LCD Display
16 kes are provided for on site programming of parameters with password protection
Device ID can be set at site
RS-485 (2 wire ) , MODBUS protocol for Master and Slave configurations.
8 number Digital inputs
For more details please cont
...More
S. No. Parameters Device Specification
1 Unit of Measurement LUX
2 Range 0 to 10,000 Lux std. , optionally 0 to 50,000 Lux
3 Accuracy +-5%
4 Working Temperature 0 to 55 deg C
5 Humidity Up-to 90%
6 Communication Port RS 485, 2 wire D+, D- and ground
7 Device ID Provided (std. factory set)
8 Data Sampling rate Ever
...More
Contact Details
POWER ENERGY CONSERVATION (I) PVT. LTD.
B-104, KAILAS ESPLANADE, LBS MARG, GHATKOPAR (W),
MUMBAI - 400086, MAHARASHTRA, INDIA
Phone:91-22-25007958 Fax:91-22-25008958
Key Personnel
Mr. Animesh Rai
(Vice President)
Mobile:+919820196007